| Range of product | Telemecanique Safety light curtains XUSL |
| Product or component type | Preventa safety module |
| Safety module name | XPSLCM |
| Safety module application | For the muting function of type 2 and type 4 safety light curtains monitored |
| Function of module | Muting |
| Safety level | Can reach PL = e with the appropriate control system and correctly wired conforming to ISO 13849-1, can reach category 4 with the appropriate control system and correctly wired conforming to ISO 13849-1, can reach SILCL 3 with the appropriate control system and correctly wired conforming to IEC 62061 |
| Safety reliability data | PFHd = 6.42E-9...5.03E-8 1/h conforming to IEC 62061, B10d = 800000 conforming to ISO 13849-1, MTTFd = 26...100 years conforming to ISO 13849-1, DC = 96.2...98.9 % conforming to ISO 13849-1 |
| Synchronisation time between inputs | - |
| Connections - terminals | Screw terminal |
| Output type | - |
| Number of additional circuits | - |
| [Us] rated supply voltage | 24 V DC - 20...20 % |