Ifm – SD5100
Flow rate meter for gases; Measuring range [m³/h] : 0.08…24.04; Display range [m³/h] : 0…28.84; Resolution [m³/h] : 0.02; Set point SP [m³/h] : 0.22…24.04; Reset point rP [m³/h] : 0.12…23.94; Analogue start point ASP [m³/h] : 0…19.24; Analogue end point AEP [m³/h] : 4.8…24.04; In steps of [m³/h] : 0.02; Measuring range [m³/h] : 0.04…14.36; Display range [m³/h] : 0…17.24; Set point SP [m³/h] : 0.14…14.36; Reset point rP [m³/h] : 0.08…14.3; Analogue start point ASP [m³/h] : 0…11.48; Analogue end point AEP [m³/h] : 2.88…14.36; Measuring range [m³/h] : 0.04…15; Display range [m³/h] : 0…18; Set point SP [m³/h] : 0.14…15; Reset point rP [m³/h] : 0.08…14.94; Analogue start point ASP [m³/h] : 0…12; Analogue end point AEP [m³/h] : 3…15; Operating voltage [V] : 18…30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 1; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; IO-Link; (configurable); Electrical design : PNP; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max. voltage drop switching output DC [V] : 2; Permanent current rating of switching output DC [mA] : 250; (per output); Number of analogue outputs : 1; Analogue current output [mA] : 4…20; (scalable); Max. load [Ω] : 500; Pulse output : consumed quantity meter; Short-circuit protection : yes; Type of short-circuit protection : pulsed; Overload protection : yes; Low flow cut-off LFC [m³/h] : < 0.26; Measuring dynamics : 1:300; Pulse value : 0.001…1 000 000 m³; In steps of : 0.001…1000 m³; Pulse length [s] : 0,062…2; Accuracy [K] : ± 2; (medium flow in the limit area of the flow measurement range); Response time [s] : 0.1; (dAP = 0); Damping for the switching output dAP in steps [s] : 0 – 0,2 – 0,4 – 0,6 – 0,8 – 1; Parameter setting options : Flow monitoring; quantity meter; Preset counter; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; medium selection; Communication interface : IO-Link; Transmission type : COM2 (38,4 kBaud); IO-Link revision : 1.1; SDCI standard : IEC 61131-9; Profiles : Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis; SIO mode : yes; Required master port type : A; Process data analogue : 3; Process data binary : 2; Min. process cycle time [ms] : 4.1; Supported DeviceIDs : Type of operation: DeviceID | Default: 263; Ambient temperature [°C] : 0…60; Storage temperature [°C] : -20…85; Max. relative air humidity [%] : 90; Materials : PBT-GF20; PC; PC; stainless steel (1.4301 / 304); FKM; Materials (wetted parts) : stainless steel (1.4301 / 304); ceramics glass passivated; PEEK; polyester; FKM; aluminium anodised; Process connection : threaded connection G 1/4 DN8; Display unit : Nl/min; Nm³/h; Nm³; °C