WL12C-3P2432A70 - Sick
Features: Sensor/ detection principle: Photoelectric retro-reflective sensor, autocollimation; Dimensions (W x H x D): 15.6 mm x 48.5 mm x 42 mm; Housing design (light emission): Rectangular; Sensing range max.: 0 m ... 5 m 1); Sensing range: 0 m ... 4 m 1); Type of light: Visible red light; Light source: PinPoint LED 2); Light spot size (distance): Ø 100 mm (3 m); Angle of dispersion: Approx. 1.5°; Wave length: 640 nm; Adjustment: IO-LinkSingle teach-in button; Diagnosis: Device contamination monitoring, Quality of teach-in; Pin 2 configuration: External input, Teach-in input, Sender off input, Detection output, logic output, Device contamination alarm output; IO-Link functions: Standard functions, advanced functions; Mechanics/electronics: Supply voltage: 10 V DC ... 30 V DC 1); Ripple: ≤ 5 Vpp 2); Power consumption: 30 mA 3); Switching output: PNP; Switching mode: Light/dark switching; Signal voltage PNP HIGH/LOW: > Uv - 2,5 V / ca. 0 V; Output current Imax.: ≤ 100 mA; Response time Q/ on Pin 2: 200 µs ... 300 µs 4) 5); Switching frequency: 1,500 Hz 6); Switching frequency Q / to pin 2: ≤ 1,500 Hz 7); Connection type: Male connector M12, 4-pin; Circuit protection: A 8)B 9)C 10)D 11); Protection class: III; Weight: 120 g; Polarisation filter: ✔; IO-Link: ✔; IO-Link version: 1.0; Transmission rate: COM2; Housing material: Metal, Zinc diecast; Optics material: Plastic, PMMA; Enclosure rating: IP66IP67; Ambient operating temperature: –40 °C ... +60 °C; Ambient storage temperature: –40 °C ... +75 °C; UL File No.: NRKH.E181493 & NRKH7.E181493; Repeatability Q/ on Pin 2:: 100 µs 5); Communication interface: Communication interface: IO-Link V1.1; Communication Interface detail: COM2 (38,4 kBaud); Cycle time: 2.3 ms; Process data length: 16 Bit; Process data structure: Bit 0 = switching signal QL1Bit 1 = switching signal QL2Bit 2 ... 15 = measuring value; VendorID: 26; DeviceID HEX: 0x8000EF; DeviceID DEC: 8388847; Smart Task: Smart Task name: Time measurement + debouncing; Logic function: DirectWINDOW; Timer function: DeactivatedOn delayOff delayON and OFF delayImpulse (one shot); Inverter: Yes; Time measurement accuracy: SIO Direct: ---SIO Logic:  - 0,7 ... + 0,7 ms ± 0,5 % of time measurement valueIOL:  - 0.9 ... + 0.9 ms ± 0.5% of the time measurement; Time measurement accuracy (e.g. accuracy for time measurement value = 1 s ): SIO Direct: ---SIO Logic: - 5,6 ... + 5,6 msIOL: - 5,9 ... + 5,9 ms; Resolution time measuring value: 1 ms; Min. Time between two process events (switches): SIO Direct: ---SIO Logic: 300 µsIOL: 500 µs; Debounce time max.: SIO Direct: ---SIO Logic: 30.000 msIOL: 30.000 ms; Switching signal QL1: Output type (dependant on the adjusted threshold); Switching signal QL2: Output type (dependant on the adjusted threshold); Measuring value: Time measurement value; Classifications: ECl@ss 5.0: 27270902; ECl@ss 5.1.4: 27270902; ECl@ss 6.0: 27270902; ECl@ss 6.2: 27270902; ECl@ss 7.0: 27270902; ECl@ss 8.0: 27270902; ECl@ss 8.1: 27270902; ECl@ss 9.0: 27270902; ECl@ss 10.0: 27270902; ECl@ss 11.0: 27270902; ETIM 5.0: EC002717; ETIM 6.0: EC002717; ETIM 7.0: EC002717; UNSPSC 16.0901: 39121528