[siemens_summary]
[catalog_children]
[catalog_search_products]
3UG Monitoring Relays

3UG Monitoring Relays

Items 49 - 60 of 107 from Siemens ⍾ Last modified Sep 7, 2025

3UG Monitoring Relays ⍾ Page 5

1345679
Product detailsAdd to RFQ
3UG4622-1AW38-0AA6-Z X95 - Siemens
DIGITAL MONITORING RELAY CURRENT MONITORING, 22.5MM FROM 0.15 TO 4.2A AC/DC SUPPLY VOLTAGE AC/DC 24 TO 240V ON DELAY 0.1S OFF DELAY 2S QUIESCENT CURRENT PRINCIPLE HYSTERESIS 0.16A 1 CO CONTACT AUTOM. RESET SCREW TERMINAL
Product detailsAdd to RFQ
3UG4622-1AW30 - Siemens
Digital monitoring relay Current monitoring, 22.5 mm from 0.05-10 A AC/DC 0vershoot and undershoot 24 to 240 V AC/DC 50 to 60 Hz DC and AC ON delay and noise pulses delay 0.1 to 20 s Hysteresis 0.01 to 5 A 1 change-over contact with or without fault buffer screw terminal Successor product for 3UG3522-1AL20, 3UG3522-1AG20 and 3UG3522-1AC48-0AA1
Product detailsAdd to RFQ
3UG4633-1AL30 - Siemens
Digital monitoring relay Voltage monitoring, 22.5 mm from 17-275 V AC/DC Overshoot and undershoot Self-powered Spike delay 0.1 to 20 s Hysteresis 0.1 to 150 V 1 CO contact With or without error buffer Screw terminals Successor product for 3UG3534, 3UG3535
Product detailsAdd to RFQ
3UG4631-1AW30 - Siemens
Digital monitoring relay Voltage monitoring, 22.5 mm from 0.1-60 V AC/DC 0vershoot and undershoot 24 to 240 V AC/DC 50 to 60 Hz DC and AC Noise pulses delay 0.1 to 20 s Hysteresis 0.1 to 30 V 1 change-over contact with or without fault buffer screw terminal Successor product for 3UG3531-1AL20, 3UG3531-1AG20
Product detailsAdd to RFQ
3UG4631-1AA30 - Siemens
DIGITAL MONITORING RELAY VOLTAGE MONITORING, 22.5MM FROM 0.1 TO 60V AC/DC OVERSHOOT AND UNDERSHOOT SUPPLY VOLTAGE: AC/DC 24V DC AND AC 50 TO 60 HZ NO GALVANIC ISOLATION FROM MEASURING CIRCUIT INTERF. PEAK DELAY 0.1 TO 20S HYSTERESIS 0.01 TO 30V 1 CO CONTACT W. OR W/O ERROR LOG SCREW TERMINAL REPLACEMENT PRODUCT FOR 3UG3531-1AC..
Product detailsAdd to RFQ
3UG4622-2AA30 - Siemens
DIGITAL MONITORING RELAY CURRENT MONITORING, 22.5MM FROM 0.05 TO 10A AC/DC OVERSHOOT AND UNDERSHOOT SUPPLY VOLTAGE: AC/DC 24V DC AND AC 50 TO 60 HZ NO GALVANIC ISOLATION FROM MEASURING CIRCUIT STARTUP AND INTERF. PEAK DELAY 0.1 TO 20S HYSTERESIS 0.01 TO 5A 1 CO CONTACT W. OR W/O ERROR LOG SPRING-LOADED CONNECTION
Product detailsAdd to RFQ
3UG4622-1AW38-0AA5-Z X95 - Siemens
DIGITAL MONITORING RELAY CURRENT MONITORING, 22.5MM FROM 0.15 TO 2A AC/DC SUPPLY VOLTAGE AC/DC 24 TO 240V ON DELAY 0.1S OFF DELAY 2S QUIESCENT CURRENT PRINCIPLE HYSTERESIS 0.16A 1 CO CONTACT AUTOM. RESET SCREW TERMINAL
Product detailsAdd to RFQ
3UG4622-2AW30 - Siemens
Digital monitoring relay Current monitoring, 22.5 mm from 0.05-10 A AC/DC 0vershoot and undershoot 24 to 240 V AC/DC 50 to 60 Hz DC and AC ON delay and noise pulses delay 0.1 to 20 s Hysteresis 0.01 to 5 A 1 change-over contact with or without fault buffer spring-type connection system
Product detailsAdd to RFQ
3UG4616-2CR20 - Siemens
Digital monitoring relay for 3-phase voltage with N-conductor Phase sequence can be activated Phase failure 3 x 90 to 400 V 50 to 60 Hz AC Undervoltage and overvoltage 90-400 V Hysteresis 1-20 V 0-20 s each for Umin and Umax 1 CO for Umin 1 CO for Umax Spring-type terminal
Product detailsAdd to RFQ
3UG4615-1CR20 - Siemens
!!! product phase-out !!! The preferred successor type is 3UG5616-1CR20 phase sequence phase failure 3x160-690 V screw digital monitoring relay for 3-phase supply voltage connectable phase sequence phase failure 3 x 160 to 690 V 50 to 60 Hz AC undervoltage and overvoltage 160-690 V hysteresis 1-20 V 0-20 s each for Umin and Umax 1 CO for Umin 1...
Product detailsAdd to RFQ
3UG4616-1CR20 - Siemens
!!! product phase-out !!! The preferred successor type is 3UG5616-1CR20 phase sequence phase failure 3x160-690 V screw digital monitoring relay for 3-phase voltage with N-conductor connectable phase sequence phase failure 3 x 90 to 400 V 50 to 60 Hz AC undervoltage and overvoltage 90-400 V hysteresis 1-20 V 0-20 s each for Umin and Umax 1 CO for Umin...
Product detailsAdd to RFQ
3UG4615-2CR20 - Siemens
Digital monitoring relay 3-phase supply voltage Phase sequence can be activated Phase failure 3 x 160 to 690 V 50 to 60 Hz AC Undervoltage and overvoltage 160-690 V Hysteresis 1-20 V 0-20 s each for Umin and Umax 1 CO for Umin 1 CO for Umax spring-type connection system