[siemens_summary]
[catalog_children]
[catalog_search_products]

3VT ⍾ Page 41

Product detailsAdd to RFQ
3VT17162DC360AA0 - Siemens
Circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=160A rated current IR=125...160A overload prot. II=800...1600A, short-circuit protection without auxiliary release without auxiliary/alarm switch
Product detailsAdd to RFQ
3VT1716-2EH46-0AA0 - Siemens
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 4-POLE, SYSTEM PROTECTION ELECTRONIC TRIP UNIT TM, LIN IN= 160A RATED CURRENT IR= 160A OVERLOAD PROTECT. II= 640A, SHORT-CIRC. PROT. N CONDUCTOR W/PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
Product detailsAdd to RFQ
3VT1712-2DB36-0AA0 - Siemens
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 3-POLE; STARTER COMBINATION ELECTRONIC TRIP UNIT TM, LIN IN= 125A RATED CURRENT II= 625... 1250A, SHORT-CIRCUIT PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
Product detailsAdd to RFQ
3VT1716-2DC36-0AA0 - Siemens
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 3-POLE, SYSTEM PROTECTION ELECTRONIC TRIP UNIT TM, LI IN= 160A RATED CURRENT IR= 125... 160A OVERLOAD PROT. II= 800... 1600A, SHORT-CIRCUIT PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
Product detailsAdd to RFQ
3VT1716-2DB36-0AA0 - Siemens
Circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole; starter combination trip unit TM, LIN In=160A rated current II=800...1600A, short-circuit protection without auxiliary release without auxiliary/alarm switch
Product detailsAdd to RFQ
3VT1716-2DA36-0AA0 - Siemens
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 3-POLE, SYSTEM PROTECTION ELECTRONIC TRIP UNIT TM, LI IN= 160A RATED CURRENT IR= 160A OVERLOAD PROTECT. II= 640A, SHORT-CIRC. PROT. W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
Product detailsAdd to RFQ
3VT1712-2EJ46-0AA0 - Siemens
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 4-POLE, SYSTEM PROTECTION ELECTRONIC TRIP UNIT TM, LIN IN= 125A RATED CURRENT IR= 100... 125A OVERLOAD PROT. II= 625... 1250A, SHORT-CIRCUIT PROTECTION N CONDUCTOR W/PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
Product detailsAdd to RFQ
3VT1712-2DC36-0AA0 - Siemens
Circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=125A rated current IR=100...125A overload prot. II=625...1250A, short-circuit protection without auxiliary release without auxiliary/alarm switch
Product detailsAdd to RFQ
3VT1712-2EG46-0AA0 - Siemens
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 4-POLE; STARTER COMBINATION ELECTRONIC TRIP UNIT TM, LIN IN= 125A RATED CURRENT II= 625... 1250A, SHORT-CIRCUIT PROTECTION N CONDUCTOR W/PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
Product detailsAdd to RFQ
3VT1712-2EC46-0AA0 - Siemens
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 4-POLE, SYSTEM PROTECTION ELECTRONIC TRIP UNIT TM, LI IN= 125A RATED CURRENT IR= 100... 125A OVERLOAD PROT. II= 625... 1250A, SHORT-CIRCUIT PROTECTION N CONDUCTOR W/O PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
Product detailsAdd to RFQ
3VT1712-2EB46-0AA0 - Siemens
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 4-POLE; STARTER COMBINATION ELECTRONIC TRIP UNIT TM, LIN IN= 125A RATED CURRENT II= 625... 1250A, SHORT-CIRCUIT PROTECTION N CONDUCTOR W/O PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
Product detailsAdd to RFQ
3VT1712-2EH46-0AA0 - Siemens
CIRCUIT BREAKER 3VT1 STANDARD BREAKING CAPACITY ICU=25KA, 415V AC 4-POLE, SYSTEM PROTECTION ELECTRONIC TRIP UNIT TM, LIN IN= 125A RATED CURRENT IR= 125A OVERLOAD PROTECTION II= 500A, SHORT-CIRC. PROT. N CONDUCTOR W/PROTECTION W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH