[siemens_summary]
[catalog_children]
[catalog_search_products]
7MF4033 / Pressure transmiters DSIII

7MF4033 / Pressure transmiters DSIII

Items 217 - 228 of 630 from Siemens ⍾ Last modified Sep 5, 2025

7MF4033 / Pressure transmiters DSIII ⍾ Page 19

Product detailsAdd to RFQ
7MF4033-1EA10-1AC7-Z A01 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,63 ... 63 bar g (9.14 ... 914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: female thread 1/2-14 npt Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable...
Product detailsAdd to RFQ
7MF4033-1EA03-1BB0 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,63 ... 63 bar g (9.14 ... 914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Housing made of stainless steel precision casting Standard design Explosion protection...
Product detailsAdd to RFQ
7MF4033-1EA10-1AC6-Z A01 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,63 ... 63 bar g (9.14 ... 914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: female thread 1/2-14 npt Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable...
Product detailsAdd to RFQ
7MF4033-1EA10-1AC6-Z A02 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,63 ... 63 bar g (9.14 ... 914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: female thread 1/2-14 npt Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable...
Product detailsAdd to RFQ
7MF4033-1EA10-1AC6-Z Y01 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,63 ... 63 bar g (9.14 ... 914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Female thread 1/2-14 NPT Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable gland 1/2-14...
Product detailsAdd to RFQ
7MF4033-1EA03-1DC0-Z A02 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,63 ... 63 bar g (9.14 ... 914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Housing made of stainless steel precision casting Standard design Explosion protection...
Product detailsAdd to RFQ
7MF4033-1EA00-2ED7-Z A01 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,63 ... 63 bar g (9.14 ... 914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing International design english inscription and documentation as cd...
Product detailsAdd to RFQ
7MF4033-1EA10-1AB6-Z A01 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,63 ... 63 bar g (9.14 ... 914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Female thread 1/2-14 NPT Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable gland M20...
Product detailsAdd to RFQ
7MF4033-1EA10-1AB6-Z A02 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,63 ... 63 bar g (9.14 ... 914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: female thread 1/2-14 npt Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable...
Product detailsAdd to RFQ
7MF4033-1EA10-1AC0-Z A02 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,63 ... 63 bar g (9.14 ... 914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Female thread 1/2-14 NPT Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable gland 1/2-14...
Product detailsAdd to RFQ
7MF4033-1EA10-1AB7-Z A01 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,63 ... 63 bar g (9.14 ... 914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Female thread 1/2-14 NPT Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable gland M20...
Product detailsAdd to RFQ
7MF4033-1EA00-2EB7-Z A01 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,63 ... 63 bar g (9.14 ... 914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing International design english inscription and documentation as cd...