7MF4433-1HA02-1BA1-Z B11 - Siemens
SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 0,3 to 30 bar (4.35 to 435 psi) , max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection:...
Product detailsAdd to RFQ
7MF4433-1GY23-1BB7-Z A02 - Siemens
SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 50 to 5000 mbar (20.08 to 2008 inH2O), max. static pressure 160 bar Version for diaphragm pressure controller. Consider additional delivery time for Remote seal....
Product detailsAdd to RFQ
7MF4433-1HA02-1AB6-Z A01 - Siemens
SITRANS P DS III / P410, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEANING SPAN: PN 160 (MWP 2320 PSI): 0,3 TO 30 BAR (4.35 TO 435 PSI) , MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION:...
Product detailsAdd to RFQ
7MF4433-1GY02-1AC1-Z B13 - Siemens
SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 50 to 5000 mbar (20.08 to 2008 inH2O), max. static pressure 160 bar Design for remote seals. note: please add the delivery time of the...
Product detailsAdd to RFQ
7MF4433-1HA02-1AC6-Z A02 - Siemens
SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 0,3 to 30 bar (4.35 to 435 psi) , max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection:...
Product detailsAdd to RFQ
7MF4433-1GA42-1AC1-Z B11 - Siemens
SITRANS P DS III / P410, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEANING SPAN: PN 160 (MWP 2320 PSI): 50 TO 5000 MBAR (20.08 TO 2008 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18...
Product detailsAdd to RFQ
7MF4433-1HA02-1AB6-Z A02 - Siemens
SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 0,3 to 30 bar (4.35 to 435 psi) , max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection:...
Product detailsAdd to RFQ
7MF4433-1GY02-1AC6-Z B11 - Siemens
SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 50 to 5000 mbar (20.08 to 2008 inH2O), max. static pressure 160 bar Version for diaphragm pressure controller. Consider additional delivery time for Remote seal....
Product detailsAdd to RFQ
7MF4433-1GY23-1BB7-Z A02 - Siemens
SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 50 to 5000 mbar (20.08 to 2008 inH2O), max. static pressure 160 bar Version for diaphragm pressure controller. Consider additional delivery time for Remote seal....
Product detailsAdd to RFQ
7MF4433-1GB02-1BB7-Z A02 - Siemens
SITRANS P DS III / P410, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEANING SPAN: PN 160 (MWP 2320 PSI): 50 TO 5000 MBAR (20.08 TO 2008 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM HASTELLOY, PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT...
Product detailsAdd to RFQ
7MF4433-1GA62-1AC7-Z A40 - Siemens
SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 50 to 5000 mbar (20.08 to 2008 inH2O), max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection: 1/4-18...
Product detailsAdd to RFQ
7MF4433-1GA42-1EB7-Z A01 - Siemens
SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 50 to 5000 mbar (20.08 to 2008 inH2O), max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection: 1/4-18...