[siemens_summary]
[catalog_children]
[catalog_search_products]

Continuous gas analyzers ⍾ Page 32

Product detailsAdd to RFQ
7MB2335-3AK16-5AA3-Z A33 - Siemens
Ultramat 23 gas analyzer for 1 Component and oxygen measurement (option) 19" plug-in unit for mounting in enclosures, gas connections 1/4 inch stainless steel,stub (1.4571), with internal sample gas pump. Component to be measured: CO Min. measuring range: 0 to 2000 vpm Max. measuring range: 0 to 10 000 vpm with O2-Sensor Without H2S-Sensor Power supply: AC 120 V, 60...
Product detailsAdd to RFQ
7MB2335-3AM06-3AA1 - Siemens
Ultramat 23 gas analyzer for 1 Component and oxygen measurement (option) 19" plug-in unit for mounting in enclosures, gas connections 1/4 inch stainless steel,stub (1.4571), with internal sample gas pump. Component to be measured: CO Min. measuring range: 0 to 1% Max. measuring range: 0 to 5% without O2-Sensor Without H2S-Sensor Power supply: AC 230 V, 50 Hz . ....
Product detailsAdd to RFQ
7MB2335-2CQ06-3AA1-Z A33 - Siemens
Ultramat 23 gas analyzer for 1 Component and oxygen measurement (option) 19-inch rack unit for installation in cabinets, sample gas connection 6 mm pipe, with internal sample gas pump Measured component: CO2 Smallest measuring range: 0 to 10% Largest measuring range: 0 to 50% Without electrochem. O2 sensor Without H2S sensor Auxiliary power: 230 V AC, 50 Hz . ....
Product detailsAdd to RFQ
7MB2335-2CP06-3AA0-Z A33 - Siemens
Ultramat 23 gas analyzer for 1 Component and oxygen measurement (option) 19" plug-in unit for mounting in enclosures, gas connections 6 mm stub, with internal sample gas pump. Component to be measured: CO2 Min. measuring range: 0 to 5% Max. measuring range: 0 to 25% without O2-Sensor Without H2S-Sensor Power supply: AC 230 V, 50 Hz . . Operator's software...
Product detailsAdd to RFQ
7MB2335-2AU86-6AA1 - Siemens
Ultramat 23 gas analyzer for 1 Component and oxygen measurement (option) 19" plug-in unit for mounting in enclosures, gas connections 6 mm stub, with internal sample gas pump. Component to be measured: CO Min. measuring range: 0 to 150 mg/m3 Max. measuring range: 0 to 750 mg/m3 with paramagnetic Oxygen measuring cell Without H2S-Sensor Power supply: AC 230 V, 60...
Product detailsAdd to RFQ
7MB2335-2NH86-3AA2-Z A13 - Siemens
Ultramat 23 gas analyzer for 1 Component and oxygen measurement (option) 19" plug-in unit for mounting in enclosures, gas connections 6 mm stub, with internal sample gas pump. Component to be measured: SO2 Min. measuring range: 0 to 500 vpm Max. measuring range: 0 to 2500 vpm with paramagnetic Oxygen measuring cell Without H2S-Sensor Power supply: AC 230 V, 50...
Product detailsAdd to RFQ
7MB2335-2AN06-3AA1-Z A13 - Siemens
Ultramat 23 gas analyzer for 1 Component and oxygen measurement (option) 19" plug-in unit for mounting in enclosures, gas connections 6 mm stub, with internal sample gas pump. Component to be measured: CO Min. measuring range: 0 to 2% Max. measuring range: 0 to 10% without O2-Sensor Without H2S-Sensor Power supply: AC 230 V, 50 Hz . . Operator's software...
Product detailsAdd to RFQ
7MB2335-2CQ06-3AA1 - Siemens
Gas analyzer ULTRAMAT 23 For measurement of 1 infrared component and oxygen and hydrogen sulfide 19-inch rack unit for installation in cabinets, Sample gas connection 6 mm pipe, with internal sample gas pump Measured component: CO2 Smallest measuring range: 0 to 10% Largest measuring range: 0 to 50% without electrochem. O2 sensor Without H2S sensor Auxiliary power: 230 V AC,...
Product detailsAdd to RFQ
7MB2335-2AU86-0AA1 - Siemens
Ultramat 23 gas analyzer for 1 Component and oxygen measurement (option) 19" plug-in unit for mounting in enclosures, gas connections 6 mm stub, with internal sample gas pump. Component to be measured: CO Min. measuring range: 0 to 150 mg/m3 Max. measuring range: 0 to 750 mg/m3 with paramagnetic Oxygen measuring cell Without H2S-Sensor Power supply: AC 100 V, 50...
Product detailsAdd to RFQ
7MB2335-2CP06-3AA2-Z A33 - Siemens
Ultramat 23 gas analyzer for 1 Component and oxygen measurement (option) 19" plug-in unit for mounting in enclosures, gas connections 6 mm stub, with internal sample gas pump. Component to be measured: CO2 Min. measuring range: 0 to 5% Max. measuring range: 0 to 25% without O2-Sensor Without H2S-Sensor Power supply: AC 230 V, 50 Hz . . Operator's software...
Product detailsAdd to RFQ
7MB2335-2AL06-3AA4 - Siemens
Ultramat 23 gas analyzer for 1 Component and oxygen measurement (option) 19" plug-in unit for mounting in enclosures, gas connections 6 mm stub, with internal sample gas pump. Component to be measured: CO Min. measuring range: 0 to 0,5% Max. measuring range: 0 to 2,5% without O2-Sensor Without H2S-Sensor Power supply: AC 230 V, 50 Hz . . Operator's software...
Product detailsAdd to RFQ
7MB2335-2AN06-3AA1 - Siemens
Ultramat 23 gas analyzer for 1 Component and oxygen measurement (option) 19" plug-in unit for mounting in enclosures, gas connections 6 mm stub, with internal sample gas pump. Component to be measured: CO Min. measuring range: 0 to 2% Max. measuring range: 0 to 10% without O2-Sensor Without H2S-Sensor Power supply: AC 230 V, 50 Hz . . Operator's software...