[siemens_summary]
[catalog_children]
[catalog_search_products]

Continuous gas analyzers ⍾ Page 46

Product detailsAdd to RFQ
7MB2121-0CA00-0AA1 - Siemens
ULTRAMAT 6 19" Built-In gas analyzer, single-channel 19" rack unit for installation in cabinets Pipe with 6 mm outer diameter CO2 Smallest measuring range: 0 to 5 vpm, largest measuring range: 0 to 100 vpm, Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without 100 to 120 V AC, 48 to 63...
Product detailsAdd to RFQ
7MB2111-1FT80-7BA1-Z B04 - Siemens
ULTRAMAT 6 Field device gas analyzer, for installation in the field, single-channel, 1 component Ferrule screw connection for pipe, outer diameter 1/4" C2H4 Smallest measuring range: 0 to 5 %, largest measuring range: 0 to 50 % Internal gas path: stainless steel pipe (mat. no. 1.4571), sample chamber (lining): Tantalum, reference chamber (flow-type): non-flow-type Without 200 to 240 V AC,...
Product detailsAdd to RFQ
7MB2121-0AF07-1AA1 - Siemens
ULTRAMAT 6 19" Built-In gas analyzer, single-channel 19" rack unit for installation in cabinets Pipe with 6 mm outer diameter CO Smallest measuring range: 0 to 300 vpm, largest measuring range: 0 to 3000 vpm, Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type AUTOCAL function with 8 digital inputs/outputs, PRFIBUS DP interface...
Product detailsAdd to RFQ
7MB2111-1NC00-1AA1-Z Y17 - Siemens
ULTRAMAT 6 gas analyzer, for installation in the field, single-channel, 1 component Ferrule screw connection for pipe, outer diameter 1/4" SO2 (TUeV) Smallest measuring range: 0 to 20 vpm, largest measuring range: 0 to 400 vpm Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without 200 to 240 V AC, 48 to...
Product detailsAdd to RFQ
7MB2121-0AB60-1AA1 - Siemens
ULTRAMAT 6E gas analyzer, single-channel 19" rack unit for installation in cabinets Pipe with 6 mm outer diameter CO Smallest measuring range: 0 to 10 vpm, largest measuring range: 0 to 200 vpm, Internal gas path: stainless steel pipe (mat. no. 1.4571), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without 200 to 240 V AC, 48 to 63 Hz...
Product detailsAdd to RFQ
7MB2121-0AL01-1AA2 - Siemens
ULTRAMAT 6E gas analyzer, single-channel 19" rack unit for installation in cabinets Pipe with 6 mm outer diameter CO Smallest measuring range: 0 to 5000 vpm, largest measuring range: 0 to 15000 vpm, Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type AUTOCAL function with 8 additional digital inputs/outputs 200 to 240 V...
Product detailsAdd to RFQ
7MB2112-1AA00-1AA1 - Siemens
Ultramat 6F-2R gas analysator for field mounting Ferrule screw connection for pipe, outer diameter 1/4" CO and NO Smallest measuring range: 0 to 100 vpm, largest measuring range: 0 to 1000 vpm (for both measured components) Internal gas path: hose made of FKM (Viton), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without Standard unit and acc. To ATEX II...
Product detailsAdd to RFQ
7MB2111-1DS20-0AA1 - Siemens
ULTRAMAT 6 gas analyzer, for installation in the field, single-channel, 1 component Ferrule screw connection for pipe, outer diameter 1/4" CH4 Smallest measuring range: 0 to 5 %, largest measuring range: 0 to 15 % Internal gas path: Pipe made of titanium, sample chamber (lining): Tantalum, reference chamber (flow-type): non-flow-type Without 100 to 120 V AC, 48 to 63 Hz...
Product detailsAdd to RFQ
7MB2111-1FV61-6AA1-Z E74 - Siemens
ULTRAMAT 6 Field device gas analyzer, for installation in the field, single-channel, 1 component Ferrule screw connection for pipe, outer diameter 1/4" C2H4 Smallest measuring range: 0 to 10 %, largest measuring range: 0 to 100 % Internal gas path: stainless steel pipe (mat. no. 1.4571), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type AUTOCAL function with 8 additional digital...
Product detailsAdd to RFQ
7MB2111-1QP60-1AA1 - Siemens
ULTRAMAT 6 Field device gas analyzer, for installation in the field, single-channel, 1 component Ferrule screw connection for pipe, outer diameter 1/4" NH3 Smallest measuring range: 0 to 1 %, largest measuring range: 0 to 10 % Internal gas path: stainless steel pipe (mat. no. 1.4571), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without 200 to 240 V AC,...
Product detailsAdd to RFQ
7MB2111-1AE60-7AA1-Z E72 - Siemens
ULTRAMAT 6 Field device gas analyzer, for installation in the field, single-channel, 1 component Ferrule screw connection for pipe, outer diameter 1/4" CO Smallest measuring range: 0 to 100 vpm, largest measuring range: 0 to 1000 vpm Internal gas path: stainless steel pipe (mat. no. 1.4571), sample chamber (lining): Aluminium, reference chamber (flow-type): non-flow-type Without 200 to 240 V AC,...
Product detailsAdd to RFQ
7MB2111-1FP20-0AA1-Z B04 - Siemens
ULTRAMAT 6 Field device gas analyzer, for installation in the field, single-channel, 1 component Ferrule screw connection for pipe, outer diameter 1/4" C2H4 Smallest measuring range: 0 to 1 %, largest measuring range: 0 to 10 % Internal gas path: Pipe made of titanium, sample chamber (lining): Tantalum, reference chamber (flow-type): non-flow-type Without 100 to 120 V AC, 48 to...