[siemens_summary]
[catalog_children]
[catalog_search_products]
DBS36E-BBG / DBS36

DBS36E-BBG / DBS36

Items 1 - 12 of 24 from SICK ⍾ Last modified Sep 3, 2025

DBS36E-BBG / DBS36 ⍾ Page 1

Product detailsAdd to RFQ
DBS36E-BBGK02000 - Sick
Performance: Pulses per revolution: 2,000; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤...
Product detailsAdd to RFQ
DBS36E-BBGK01000 - Sick
Performance: Pulses per revolution: 1,000; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤...
Product detailsAdd to RFQ
DBS36E-BBGK01024 - Sick
Performance: Pulses per revolution: 1,024; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤...
Product detailsAdd to RFQ
DBS36E-BBGL00200 - Sick
Performance: Pulses per revolution: 200; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤...
Product detailsAdd to RFQ
DBS36E-BBGN01024 - Sick
Performance: Pulses per revolution: 1,024; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤...
Product detailsAdd to RFQ
DBS36E-BBGK02048 - Sick
Performance: Pulses per revolution: 2,048; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤...
Product detailsAdd to RFQ
DBS36E-BBGK02500 - Sick
Performance: Pulses per revolution: 2,500; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤...
Product detailsAdd to RFQ
DBS36E-BBGZ00S47 - Sick
Features: Special device: ✔; Specialty: Customized Resolution: 1pprCustomized PIN allocation HTL/Push pull 7 V ... 27 V A, B channelsSpecified operating conditions: one cycle of 1 min. every 30 min., only seldom (not every day) the motor makes a cycle of 20 min.Temperature range down to –30 °CPremounted sleeves in black and violet; Standard reference device: DBS36E-BBGJ01024, 1077388; Performance: Pulses...
Product detailsAdd to RFQ
DBS36E-BBGP01000 - Sick
Performance: Pulses per revolution: 1,000; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤...
Product detailsAdd to RFQ
DBS36E-BBGL00100 - Sick
Performance: Pulses per revolution: 100; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤...
Product detailsAdd to RFQ
DBS36E-BBGM01000 - Sick
Performance: Pulses per revolution: 1,000; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤...
Product detailsAdd to RFQ
DBS36E-BBGJ00500 - Sick
Performance: Pulses per revolution: 500; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤...