[siemens_summary]
[catalog_children]
[catalog_search_products]

DBS60 ⍾ Page 29

Product detailsAdd to RFQ
DBS60E-S4CJ00100 - Sick
Performance: Pulses per revolution: 100; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: + 300...
Product detailsAdd to RFQ
DBS60E-S4EC00060 - Sick
Performance: Pulses per revolution: 60; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4CP05000 - Sick
Performance: Pulses per revolution: 5,000; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 36° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 10 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: + 300...
Product detailsAdd to RFQ
DBS60E-S4CK05000 - Sick
Performance: Pulses per revolution: 5,000; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 36° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 10 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: + 300...
Product detailsAdd to RFQ
DBS60E-S4CK02048 - Sick
Performance: Pulses per revolution: 2,048; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: + 300...
Product detailsAdd to RFQ
DBS60E-S4CK02000 - Sick
Performance: Pulses per revolution: 2,000; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: + 300...
Product detailsAdd to RFQ
DBS60E-S4CP01024 - Sick
Performance: Pulses per revolution: 1,024; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: + 300...
Product detailsAdd to RFQ
DBS60E-S4EA00500 - Sick
Performance: Pulses per revolution: 500; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4EA00100 - Sick
Performance: Pulses per revolution: 100; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-S4CL04096 - Sick
Performance: Pulses per revolution: 4,096; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 36° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 10 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: + 300...
Product detailsAdd to RFQ
DBS60E-S4CC03600 - Sick
Performance: Pulses per revolution: 3,600; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 36° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 10 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: + 300...
Product detailsAdd to RFQ
DBS60E-S4CA00S87 - Sick
Features: Special device: ✔; Specialty: Shaft 10 x 19 mm roundFace mount flange with M3 & M4 (details in dimensional drawing)Connector M23, 12-pin, radial with customer specific pin allocation; Standard reference device: DBS60E-S4CA05000, 1075365; Performance: Pulses per revolution: 5,000; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 36° / pulses per revolution; Error limits: Measuring step deviation...