[siemens_summary]
[catalog_children]
[catalog_search_products]

DBS60 ⍾ Page 44

Product detailsAdd to RFQ
DBS60E-RGEC00512 - Sick
Performance: Pulses per revolution: 512; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-RGFN02500 - Sick
Performance: Pulses per revolution: 2,500; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Number of signal channels: 6-channel; Initialization time: < 5 ms 2); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-REFCD1024 - Sick
Performance: Pulses per revolution: 1,024; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Number of signal channels: 6-channel; Initialization time: < 5 ms 2); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-REFAC1024 - Sick
Performance: Pulses per revolution: 1,024; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Number of signal channels: 6-channel; Initialization time: < 5 ms 2); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-REFAA3600 - Sick
Performance: Pulses per revolution: 3,600; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 36° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 10 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Number of signal channels: 6-channel; Initialization time: < 5 ms 2); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-REFL02000 - Sick
Performance: Pulses per revolution: 2,000; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Number of signal channels: 6-channel; Initialization time: < 5 ms 2); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-RGAK01024 - Sick
Performance: Pulses per revolution: 1,024; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: + 300...
Product detailsAdd to RFQ
DBS60E-RGEAA4096 - Sick
Performance: Pulses per revolution: 4,096; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 36° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 10 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-REFN02048 - Sick
Performance: Pulses per revolution: 2,048; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Number of signal channels: 6-channel; Initialization time: < 5 ms 2); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-REFCA1000 - Sick
Performance: Pulses per revolution: 1,000; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL 1); Number of signal channels: 6-channel; Initialization time: < 5 ms 2); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-REEK01024 - Sick
Performance: Pulses per revolution: 1,024; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...
Product detailsAdd to RFQ
DBS60E-REEK00100 - Sick
Performance: Pulses per revolution: 100; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: +...