C4P-PA0603S001 - Sick
Features: Application: Normal industrial environment; System part: Set; Resolution: 30 mm; Scanning range: 30 m; Protective field height: 600 mm; Response time: 10 ms (Uncoded)15 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Integrated laser alignment aid: ✔; Items supplied: SenderReceiver2 system plugs, pre-mounted4 FlexFix bracketsT-connector with pushbutton for laser alignment aidTest rod with diameter...
Product detailsAdd to RFQ
C4P-EX06011C00 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 600 mm; Response time: 13 ms (Uncoded)22 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items...
Product detailsAdd to RFQ
C4P-EX03031C00 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Receiver; Resolution: 30 mm; Scanning range: 30 m; Protective field height: 300 mm; Response time: 9 ms (Uncoded)12 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items...
Product detailsAdd to RFQ
C4P-EX03011C00 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 300 mm; Response time: 11 ms (Uncoded)16 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items...
Product detailsAdd to RFQ
C4P-EG18011C00 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 1,800 mm; Response time: 20 ms (Uncoded)45 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting...
Product detailsAdd to RFQ
C4P-EX13531C00 - Sick
Features: Application: Explosive areas; Ex-approvals: ATEX for gas: II 3G Ex ec op is IIC T4 GcATEX for dust: II 3D Ex tc IIIC T135°C Dc; System part: Receiver; Resolution: 30 mm; Scanning range: 30 m; Protective field height: 1,350 mm; Response time: 12 ms (Uncoded)21 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items...
Product detailsAdd to RFQ
C4P-EG16531D00 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Receiver; Resolution: 30 mm; Scanning range: 30 m; Protective field height: 1,650 mm; Response time: 13 ms (Uncoded)23 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; End cap with integrated LED: ✔; Items supplied: ReceiverTest rod with diameter corresponding to the resolution...
Product detailsAdd to RFQ
C4P-EG07511C00 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 750 mm; Response time: 13 ms (Uncoded)25 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting...
Product detailsAdd to RFQ
C4P-EG15011C00 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Receiver; Resolution: 14 mm; Scanning range: 20 m; Protective field height: 1,500 mm; Response time: 18 ms (Uncoded)40 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting...
Product detailsAdd to RFQ
C4P-EG04531C00 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Receiver; Resolution: 30 mm; Scanning range: 30 m; Protective field height: 450 mm; Response time: 10 ms (Uncoded)14 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting...
Product detailsAdd to RFQ
C4P-EG12031C00 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Receiver; Resolution: 30 mm; Scanning range: 30 m; Protective field height: 1,200 mm; Response time: 12 ms (Uncoded)20 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting...
Product detailsAdd to RFQ
C4P-EG07531C00 - Sick
Features: Application: Areas where coolants, lubricants and cleaning agents are used; System part: Receiver; Resolution: 30 mm; Scanning range: 30 m; Protective field height: 750 mm; Response time: 11 ms (Uncoded)16 ms (code 1 or code 2); No blind zones: Yes; Synchronization: Optical synchronisation; Items supplied: ReceiverTest rod with diameter corresponding to the resolution of the safety light curtainSafety instructionMounting...