[siemens_summary]
[catalog_children]
[catalog_search_products]
DFS60 Inox

DFS60 Inox

Items 1 - 12 of 96 from SICK ⍾ Last modified Sep 3, 2025

DFS60 Inox ⍾ Page 1

Product detailsAdd to RFQ
DFS60I-S4PC10000 - Sick
Performance: Pulses per revolution: 10,000 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL; Factory setting: Factory setting: output level TTL; Number of signal channels: 6-channel; Programmable/configurable: ✔; Initialization time: 32 ms 1)30 ms; Output frequency: ≤...
Product detailsAdd to RFQ
DFS60I-S4PC32678 - Sick
Performance: Pulses per revolution: 32,678 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.002°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL; Factory setting: Factory setting: output level TTL; Number of signal channels: 6-channel; Programmable/configurable: ✔; Initialization time: 32 ms 1)30 ms; Output frequency: ≤...
Product detailsAdd to RFQ
DFS60I-S4VK03600 - Sick
Performance: Pulses per revolution: 3,600 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L ≡ 0 - 3 V, H ≡ 4.0...
Product detailsAdd to RFQ
DFS60I-S4PL65536 - Sick
Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL; Factory setting: Factory setting: output level TTL; Number of signal channels: 6-channel; Programmable/configurable: ✔; Initialization time: 32 ms 1)30 ms; Output frequency: ≤ 820...
Product detailsAdd to RFQ
DFS60I-S4WC01800 - Sick
Performance: Pulses per revolution: 1,800 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L ≡ 0 - 3 V, H ≡...
Product detailsAdd to RFQ
DFS60I-S4PK65536 - Sick
Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL; Factory setting: Factory setting: output level TTL; Number of signal channels: 6-channel; Programmable/configurable: ✔; Initialization time: 32 ms 1)30 ms; Output frequency: ≤ 820...
Product detailsAdd to RFQ
DFS60I-S4PC65536 - Sick
Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL; Factory setting: Factory setting: output level TTL; Number of signal channels: 6-channel; Programmable/configurable: ✔; Initialization time: 32 ms 1)30 ms; Output frequency: ≤ 820...
Product detailsAdd to RFQ
DFS60I-S4WC01000 - Sick
Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L ≡ 0 - 3 V, H ≡...
Product detailsAdd to RFQ
DFS60I-S4VC65536 - Sick
Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L ≡ 0 - 3 V, H ≡ 4.0 -...
Product detailsAdd to RFQ
DFS60I-S4NM01024 - Sick
Performance: Periods per revolution: 1,024; Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: Sin/Cos 1); Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 200 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load); Load...
Product detailsAdd to RFQ
DFS60I-S4NL01024 - Sick
Performance: Periods per revolution: 1,024; Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: Sin/Cos 1); Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 200 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load); Load...
Product detailsAdd to RFQ
DFS60I-S4PC01024 - Sick
Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / HTL; Factory setting: Factory setting: output level TTL; Number of signal channels: 6-channel; Programmable/configurable: ✔; Initialization time: 32 ms 1)30 ms; Output frequency: ≤ 820...