[siemens_summary]
[catalog_children]
[catalog_search_products]
DFS60A-BH / DFS60

DFS60A-BH / DFS60

Items 25 - 29 of 29 from SICK ⍾ Last modified Sep 3, 2025

DFS60A-BH / DFS60 ⍾ Page 3

Product detailsAdd to RFQ
DFS60A-BHAK01024 - Sick
Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 820 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load); Electrical...
Product detailsAdd to RFQ
DFS60A-BHAN01024 - Sick
Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 820 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load); Electrical...
Product detailsAdd to RFQ
DFS60A-BHCC16384 - Sick
Performance: Pulses per revolution: 16,384 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 820 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without load);...
Product detailsAdd to RFQ
DFS60A-BHEK01024 - Sick
Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 820 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60A-BHAC19200 - Sick
Performance: Pulses per revolution: 19,200 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.002°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 820 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load);...