[siemens_summary]
[catalog_children]
[catalog_search_products]
DFS60A-S4 / DFS60

DFS60A-S4 / DFS60

Items 25 - 36 of 38 from SICK ⍾ Last modified Sep 3, 2025

DFS60A-S4 / DFS60 ⍾ Page 3

Product detailsAdd to RFQ
DFS60A-S4CM20000 - Sick
Performance: Pulses per revolution: 20,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.002°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 820 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60A-S4CK00256 - Sick
Performance: Pulses per revolution: 256 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 820 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without load);...
Product detailsAdd to RFQ
DFS60A-S4AM65000 - Sick
Performance: Pulses per revolution: 65,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.002°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 820 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load);...
Product detailsAdd to RFQ
DFS60A-S4CA50000 - Sick
Performance: Pulses per revolution: 50,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.002°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 820 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60A-S4CA02048 - Sick
Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 820 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without load);...
Product detailsAdd to RFQ
DFS60A-S4AN65536 - Sick
Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 820 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load); Electrical...
Product detailsAdd to RFQ
DFS60A-S4AK32768 - Sick
Performance: Pulses per revolution: 32,768 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 820 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load); Electrical...
Product detailsAdd to RFQ
DFS60A-S4AM50000 - Sick
Performance: Pulses per revolution: 50,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.002°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 820 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load);...
Product detailsAdd to RFQ
DFS60A-S4AK36000 - Sick
Performance: Pulses per revolution: 36,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.002°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 820 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load);...
Product detailsAdd to RFQ
DFS60A-S4AL08192 - Sick
Performance: Pulses per revolution: 8,192 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 820 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load); Electrical...
Product detailsAdd to RFQ
DFS60A-S4AK08192 - Sick
Performance: Pulses per revolution: 8,192 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 820 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load); Electrical...
Product detailsAdd to RFQ
DFS60A-S4AK02000 - Sick
Performance: Pulses per revolution: 2,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 820 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load);...