DFS60B-BDE / DFS60

DFS60B-BDE / DFS60

Items 49 - 60 of 70 from SICK ⍾ Last modified Sep 4, 2025

DFS60B-BDE / DFS60 ⍾ Page 5

Product detailsAdd to RFQ
DFS60B-BDEA00004 - Sick
DFS60, Rotary.
Product detailsAdd to RFQ
DFS60B-BDEA00100 - Sick
DFS60, Rotary.
Product detailsAdd to RFQ
DFS60B-BDEA00005 - Sick
DFS60, Rotary.
Product detailsAdd to RFQ
DFS60B-BDEA00060 - Sick
DFS60, Rotary. Electrical interface: HTL/Push pull, Connector M23, 12-pin, radial.
Product detailsAdd to RFQ
DFS60B-BDEM00720 - Sick
Performance: Pulses per revolution: 720 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60B-BDEK08192 - Sick
Performance: Pulses per revolution: 8,192 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60B-BDEL00256 - Sick
Performance: Pulses per revolution: 256 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60B-BDEK01000 - Sick
Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60B-BDEM00010 - Sick
Performance: Pulses per revolution: 10 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.08°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60B-BDEC03500 - Sick
Performance: Pulses per revolution: 3,500 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product detailsAdd to RFQ
DFS60B-BDEM00004 - Sick
Performance: Pulses per revolution: 4 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.05°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W (without...
Product detailsAdd to RFQ
DFS60B-BDEL10000 - Sick
Performance: Pulses per revolution: 10,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...