[siemens_summary]
[catalog_children]
[catalog_search_products]
DFS60B-TG / DFS60

DFS60B-TG / DFS60

Items 49 - 60 of 96 from SICK ⍾ Last modified Sep 4, 2025

DFS60B-TG / DFS60 ⍾ Page 5

Product detailsAdd to RFQ
DFS60B-TGVA08192 - Sick
Performance: Pulses per revolution: 8,192 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 - Us V...
Product detailsAdd to RFQ
DFS60B-TGWA00020 - Sick
Performance: Pulses per revolution: 20 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.08°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 -...
Product detailsAdd to RFQ
DFS60B-TGWA00360 - Sick
Performance: Pulses per revolution: 360 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 -...
Product detailsAdd to RFQ
DFS60B-TGVA01024 - Sick
Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 - Us V...
Product detailsAdd to RFQ
DFS60B-TGWA01024 - Sick
Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 - Us...
Product detailsAdd to RFQ
DFS60B-TGVA10000 - Sick
Performance: Pulses per revolution: 10,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 - Us...
Product detailsAdd to RFQ
DFS60B-TGPZ00S79 - Sick
Features: Special device: ✔; Specialty: Through hollow shaft Ø 14 mm, clamping at the back (B side)Stator coupling 4071692 premountedProgrammable, preprogrammed to HTL/push pullCable, 8-wire, universal length of 1.0 m with M23 male connector on end of cable plus customized pin assignmentProgrammable via PGT-10-S-S03, preprogrammed to 1024 lines; Standard reference device: DFS60B-TGPK10000, 1036926; Performance: Pulses per revolution: 1,024 1); Measuring...
Product detailsAdd to RFQ
DFS60B-TGNL01024 - Sick
Performance: Periods per revolution: 1,024; Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: Sin/Cos 1); Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 200 kHz; Operating current: 40 mA (without load); Load resistance: ≤ 120 Ω; Electrical data: Connection...
Product detailsAdd to RFQ
DFS60B-TGPZ00S39 - Sick
Features: Special device: ✔; Specialty: Through hollow shaft Ø 14 mm, clamping at the back (B side)Stator coupling 4071692 premountedProgrammable, preprogrammed to HTL/push pullCable, 8-wire, universal length of 1.0 m with M23 male connector on end of cable plus customized pin assignmentProgrammable via PGT-10-S-S03, preprogrammed to 1024 lines; Standard reference device: DFS60B-TGPK10000, 1036926; Performance: Pulses per revolution: 1,024 1); Measuring...
Product detailsAdd to RFQ
DFS60B-TGUA04096 - Sick
Performance: Pulses per revolution: 4,096 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 - Us V...
Product detailsAdd to RFQ
DFS60B-TGUA05000 - Sick
Performance: Pulses per revolution: 5,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 - Us...
Product detailsAdd to RFQ
DFS60B-TGNK01024 - Sick
Performance: Periods per revolution: 1,024; Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: Sin/Cos 1); Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 200 kHz; Operating current: 40 mA (without load); Load resistance: ≤ 120 Ω; Electrical data: Connection...