[siemens_summary]
[catalog_children]
[catalog_search_products]

Encoders ⍾ Page 626

Product detailsAdd to RFQ
DBS50E-S5RP01200 - Sick
Performance: Pulses per revolution: 1,200; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: Open Collector; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤ 300 kHz;...
Product detailsAdd to RFQ
DBS60B-S4HA10000 - Sick
Performance: Pulses per revolution: 10,000; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 36° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 10 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: + 300...
Product detailsAdd to RFQ
DBS60B-S1HC10000 - Sick
Performance: Pulses per revolution: 10,000; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 36° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 10 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: + 300...
Product detailsAdd to RFQ
DBS60B-BHHA10000 - Sick
Performance: Pulses per revolution: 10,000; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 36° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 10 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: + 300...
Product detailsAdd to RFQ
DBS50E-SZAJ00S09 - Sick
Features: Special device: ✔; Specialty: Solid shaft Ø 5/16''19 mm length with flat form on the full length; Standard reference device: DBS50E-S5AJ01024, 1060870; Performance: Pulses per revolution: 1,024; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication...
Product detailsAdd to RFQ
DBS50E-S5PM02000 - Sick
Performance: Pulses per revolution: 2,000; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: Open Collector; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤ 300 kHz;...
Product detailsAdd to RFQ
DBS50E-S5PL01000 - Sick
DBS50. Electrical interface: 4.5 V ... 5.5 V, open collector, Cable, 8-pin, universal, 3 m.
Product detailsAdd to RFQ
DBS60B-S4HA08192 - Sick
Performance: Pulses per revolution: 8,192; Measuring step: ≤ 90° electric/pulses per revolution; Measuring step deviation: ± 36° / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: ≤ 0.5 ± 10 %; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: < 5 ms 1); Output frequency: + 300...
Product detailsAdd to RFQ
DBS50E-S5RK00100 - Sick
Performance: Pulses per revolution: 100; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: Open Collector; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤ 300 kHz;...
Product detailsAdd to RFQ
DBS50E-S5RK02500 - Sick
Performance: Pulses per revolution: 2,500; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: Open Collector; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤ 300 kHz;...
Product detailsAdd to RFQ
DBS50E-S5RK00500 - Sick
Performance: Pulses per revolution: 500; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: Open Collector; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤ 300 kHz;...
Product detailsAdd to RFQ
DBS50E-S5RK00360 - Sick
Performance: Pulses per revolution: 360; Measuring step: 90° electric/pulses per revolution; Measuring step deviation: ± 18° / pulses per revolution; Error limits: ± 54° / pulses per revolution; Duty cycle: ≤ 0.5 ± 5 %; Interfaces: Communication interface: Incremental; Communication Interface detail: Open Collector; Number of signal channels: 3 channel; Initialization time: < 3 ms; Output frequency: ≤ 300 kHz;...