[siemens_summary]
[catalog_children]
[catalog_search_products]
FFU

FFU

Items 1 - 12 of 38 from SICK ⍾ Last modified Sep 3, 2025

FFU ⍾ Page 1

Product detailsAdd to RFQ
FFUS25-1G1IO - Sick
Ultrasonic flowmeter. Process temperature: 0 °C ... 80 °C. Maximum flow: 240 l/min. Process connection: G 1 1/4.
Product detailsAdd to RFQ
FFUS25-1N1SR - Sick
Features: Measurement principle: Ultrasonic sensor; Medium: Fluids; Nominal width measuring tube: DN 25; Process temperature: 0 °C ... +80 °C; Process pressure: Max. 10 bar; Performance: Minimim flow: ≥ 5 l/min 1); Maximum flow: 0 l/min ... 240 l/min; Inlet zone: 40 cm; Output zone: 20 cm; Conductivity: No limitation; Accuracy of sensor element: 2 % of final value 2);...
Product detailsAdd to RFQ
FFUS25-1G1SR - Sick
Ultrasonic flowmeter. Process temperature: 0 °C ... 80 °C. Maximum flow: 240 l/min. Process connection: G 1 1/4.
Product detailsAdd to RFQ
FFUS25-1C1SR - Sick
Features: Measurement principle: Ultrasonic sensor; Medium: Fluids; Nominal width measuring tube: DN 25; Process temperature: 0 °C ... +80 °C; Process pressure: Max. 10 bar; Performance: Minimim flow: ≥ 5 l/min 1); Maximum flow: 0 l/min ... 240 l/min; Inlet zone: 40 cm; Output zone: 20 cm; Conductivity: No limitation; Accuracy of sensor element: 2 % of final value 2);...
Product detailsAdd to RFQ
FFUS25-1N1IO - Sick
Ultrasonic flowmeter. Process temperature: 0 °C ... 80 °C. Maximum flow: 240 l/min. Process connection: 1 1/4" NPT.
Product detailsAdd to RFQ
FFUS20-1G1SR - Sick
Ultrasonic flowmeter. Process temperature: 0 °C ... 80 °C. Maximum flow: 60 l/min. Process connection: G 1.
Product detailsAdd to RFQ
FFUS20-1C1IO - Sick
Ultrasonic flowmeter. Process temperature: 0 °C ... 80 °C. Maximum flow: 60 l/min. Process connection: Clamp (DIN 11864-3) DN 20 form A.
Product detailsAdd to RFQ
FFUS20-1C1SR - Sick
Features: Measurement principle: Ultrasonic sensor; Medium: Fluids; Nominal width measuring tube: DN 20; Process temperature: 0 °C ... +80 °C; Process pressure: Max. 10 bar; Performance: Minimim flow: ≥ 3.5 l/min 1); Maximum flow: 0 l/min ... 60 l/min; Inlet zone: 40 cm; Output zone: 10 cm; Conductivity: No limitation; Accuracy of sensor element: 2 % of final value 2);...
Product detailsAdd to RFQ
FFUS25-1C1IO - Sick
Ultrasonic flowmeter. Process temperature: 0 °C ... 80 °C. Maximum flow: 240 l/min. Process connection: Clamp (DIN 11864-3) DN 25 form A.
Product detailsAdd to RFQ
FFUS15-1G1IO - Sick
Ultrasonic flowmeter. Process temperature: 0 °C ... 80 °C. Maximum flow: 36 l/min. Process connection: G 3/4.
Product detailsAdd to RFQ
FFUS20-1N1IO - Sick
Ultrasonic flowmeter. Process temperature: 0 °C ... 80 °C. Maximum flow: 60 l/min. Process connection: 1" NPT.
Product detailsAdd to RFQ
FFUS20-1G1IO - Sick
Ultrasonic flowmeter. Process temperature: 0 °C ... 80 °C. Maximum flow: 60 l/min. Process connection: G 1.