[siemens_summary]
[catalog_children]
[catalog_search_products]

Fieldbus components ⍾ Page 2

Product detailsAdd to RFQ
AL1331 - Ifm
IO-Link master with EtherCAT interface; Protection class : III; Max. current load total [A] : 3.6; Total number of inputs and outputs : 8; (configurable); Number of digital inputs : 8; (IO-Link Port Class A: 4 x 2); Switching level high [V] : 11...28; Switching level low [V] : 0...5; Digital inputs protected against short circuits : yes; Number of...
Product detailsAdd to RFQ
AL1333 - Ifm
IO-Link master with EtherCAT interface; Protection class : III; Max. current load total [A] : 3.6; Total number of inputs and outputs : 16; (configurable); Number of digital inputs : 16; (IO-Link Port Class A: 8 x 2); Switching level high [V] : 11...28; Switching level low [V] : 0...5; Digital inputs protected against short circuits : yes; Number of...
Product detailsAdd to RFQ
AL1341 - Ifm
IO-Link master with Modbus TCP interface; Protection class : III; Max. current load total [A] : 3.6; Total number of inputs and outputs : 8; (configurable); Number of digital inputs : 8; (IO-Link Port Class A: 4 x 2); Switching level high [V] : 11...28; Switching level low [V] : 0...5; Digital inputs protected against short circuits : yes; Number...
Product detailsAdd to RFQ
AL1303 - Ifm
IO-Link master with PROFINET interface; Protection class : III; Max. current load total [A] : 3.6; Total number of inputs and outputs : 16; (configurable); Number of digital inputs : 16; (IO-Link Port Class A: 8 x 2); Switching level high [V] : 11...28; Switching level low [V] : 0...5; Digital inputs protected against short circuits : yes; Number of...
Product detailsAdd to RFQ
AL1301 - Ifm
IO-Link master with PROFINET interface; Protection class : III; Max. current load total [A] : 3.6; Total number of inputs and outputs : 8; (configurable); Number of digital inputs : 8; (IO-Link Port Class A: 4 x 2); Switching level high [V] : 11...28; Switching level low [V] : 0...5; Digital inputs protected against short circuits : yes; Number of...
Product detailsAdd to RFQ
AL1321 - Ifm
IO-Link master with EtherNet/IP interface; Protection class : III; Max. current load total [A] : 3.6; Total number of inputs and outputs : 8; (configurable); Number of digital inputs : 8; (IO-Link Port Class A: 4 x 2); Switching level high [V] : 11...28; Switching level low [V] : 0...5; Digital inputs protected against short circuits : yes; Number of...
Product detailsAdd to RFQ
AL1323 - Ifm
IO-Link master with EtherNet/IP interface; Protection class : III; Max. current load total [A] : 3.6; Total number of inputs and outputs : 16; (configurable); Number of digital inputs : 16; (IO-Link Port Class A: 8 x 2); Switching level high [V] : 11...28; Switching level low [V] : 0...5; Digital inputs protected against short circuits : yes; Number of...