SICK
>
Encoders
>
Incremental encoders
[siemens_summary]
[catalog_children]
[catalog_search_products]
Incremental encoders
Items 3757 - 3768 of 6146
from
SICK
⍾ Last modified Sep 3, 2025
▲
DBS36
DBS50
DBS60
DBS60 Inox
DDS36
DDS50
DFS60
DFS60 Inox
DGS34
DGS35
DKS40
DRS26
DUS60
Search
Incremental encoders ⍾ Page 314
«
1
…
312
313
314
315
316
…
513
»
Product details
Add to RFQ
DFS60B-BFPL10000 - Sick
DFS60, Rotary. Electrical interface: 4.5 V ... 32 V, TTL/HTL programmable, Cable, 8-pin, universal, 3 m.
Product details
Add to RFQ
DFS60B-BGAA02500 - Sick
Performance: Pulses per revolution: 2,500 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load);...
Product details
Add to RFQ
DFS60B-BGAA01024 - Sick
Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load); Electrical...
Product details
Add to RFQ
DFS60B-BFEK00100 - Sick
Performance: Pulses per revolution: 100 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product details
Add to RFQ
DFS60B-BGAC10000 - Sick
Performance: Pulses per revolution: 10,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load);...
Product details
Add to RFQ
DFS60B-BFEK05000 - Sick
Performance: Pulses per revolution: 5,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Power consumption: ≤ 0.5 W...
Product details
Add to RFQ
DFS60B-BFPK10000 - Sick
DFS60, Rotary. Electrical interface: Cable, 8-pin, universal, 1.5 m, TTL/HTL programmable.
Product details
Add to RFQ
DFS60B-BFPC10000 - Sick
DFS60, Rotary. Electrical interface: 4.5 V ... 32 V, TTL/HTL programmable, Connector M12, 8-pin, radial.
Product details
Add to RFQ
DFS60B-BGAC02000 - Sick
Performance: Pulses per revolution: 2,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: TTL / RS-422; Number of signal channels: 6-channel; Initialization time: 40 ms; Output frequency: ≤ 600 kHz; Load current: ≤ 30 mA; Operating current: 40 mA (without load);...
Product details
Add to RFQ
DFS60B-BEWA01000 - Sick
Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 -...
Product details
Add to RFQ
DFS60B-BEWA00400 - Sick
Performance: Pulses per revolution: 400 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 -...
Product details
Add to RFQ
DFS60B-BEWA00512 - Sick
Performance: Pulses per revolution: 512 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: Communication interface: Incremental; Communication Interface detail: HTL / Push pull; Number of signal channels: 6-channel; 0-set function via hardware pin: ✔; 0-SET function: H-active, L = 0 - 3 V, H = 4,0 - Us...
« Prev page