[siemens_summary]
[catalog_children]
[catalog_search_products]

Inductive sensors ⍾ Page 14

Product detailsAdd to RFQ
NG5010 - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : II; Electrical...
Product detailsAdd to RFQ
NF5002 - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : III; Electrical...
Product detailsAdd to RFQ
NG5004 - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : II; Electrical...
Product detailsAdd to RFQ
NF5008 - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : III; Electrical...
Product detailsAdd to RFQ
NF5001 - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : III; Electrical...
Product detailsAdd to RFQ
NF500A - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : III; Electrical...
Product detailsAdd to RFQ
NF5012 - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : III; Electrical...
Product detailsAdd to RFQ
NF5010 - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : III; Electrical...
Product detailsAdd to RFQ
NF5023 - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : III; Electrical...
Product detailsAdd to RFQ
NF501A - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : III; Electrical...
Product detailsAdd to RFQ
NF5030 - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : III; Electrical...
Product detailsAdd to RFQ
NG5003 - Ifm
Inductive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...30; (when used outside the hazardous area); Protection class : II; Electrical...