[siemens_summary]
[catalog_children]
[catalog_search_products]

IO-Link ⍾ Page 1

Product detailsAdd to RFQ
E30430 - Ifm
IO-Link display; Operating voltage [V] : 18...30 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Parameter setting options : display, indication; Communication interface : IO-Link; Transmission type : COM2 (38,4 kBaud); IO-Link revision : 1.1; SDCI standard : IEC 61131-9; Profiles : Smart Sensor: Process Data Variable; Device Identification,...
Product detailsAdd to RFQ
E30391 - Ifm
IO-Link display; Operating voltage [V] : 18...30 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Parameter setting options : display, indication (figure, text, QR code); Communication interface : IO-Link; Transmission type : COM2 (38,4 kBaud); IO-Link revision : 1.1; SDCI standard : IEC 61131-9; Profiles : Smart Sensor: Process...
Product detailsAdd to RFQ
SM9400 - Ifm
Magnetic-inductive flow meter; Operating voltage [V] : 18...32 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs :...
Product detailsAdd to RFQ
SM8500 - Ifm
Magnetic-inductive flow meter; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs : 2; Output...
Product detailsAdd to RFQ
SM8400 - Ifm
Magnetic-inductive flow meter; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs : 2; Output...
Product detailsAdd to RFQ
SM8601 - Ifm
Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs : 2; Output function : normally...
Product detailsAdd to RFQ
SM9500 - Ifm
Magnetic-inductive flow meter; Operating voltage [V] : 18...32 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs :...
Product detailsAdd to RFQ
SM9601 - Ifm
Operating voltage [V] : 18...32 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs : 2; Output function...
Product detailsAdd to RFQ
PV7701 - Ifm
Pressure switch with IO-Link; Operating voltage [V] : 18...30 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : < 0.3; Total number of outputs : 2; Output signal : switching signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs : 2; Output function...
Product detailsAdd to RFQ
PV7604 - Ifm
Electronic pressure monitor; Operating voltage [V] : 18...30 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : < 0.3; Total number of outputs : 2; Output signal : switching signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs : 2; Output function :...
Product detailsAdd to RFQ
PV7623 - Ifm
Electronic pressure monitor; Operating voltage [V] : 18...30 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : < 0.3; Total number of outputs : 2; Output signal : switching signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs : 2; Output function :...
Product detailsAdd to RFQ
PV7603 - Ifm
Electronic pressure monitor; Operating voltage [V] : 18...30 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : < 0.3; Total number of outputs : 2; Output signal : switching signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs : 2; Output function :...