[siemens_summary]
[catalog_children]
[catalog_search_products]
Linear encoders

Linear encoders

Items 61 - 72 of 233 from SICK ⍾ Last modified Sep 4, 2025

Linear encoders ⍾ Page 6

Product detailsAdd to RFQ
MAX48N-22C0BCB1540 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning, speed; Measuring rangePosition (F.S.)0 mm ... 1,540 mm 1)Speed0 … 1,000 mm/s: Measuring range; Unusable rangeNull zone30 mmDamping zone36 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 1 ms; Transmission rate (cycle time): CANopen (0 ... 65,535 ms),...
Product detailsAdd to RFQ
MAX48N-22V10AC0500 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 240 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone36 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-22V10AC0100 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring range: 50 mm ... 100 mm; Unusable rangeZeroset30 mmEnd point (attenuation)36 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Setting point (zero and end point of the piston stroke): ≤ 1 mm; Resolution: Typ. 0.1...
Product detailsAdd to RFQ
MAX48N-22C0CCB1592 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning, speed; Measuring rangePosition (F.S.)0 mm ... 1,592 mm 1)Speed0 … 1,000 mm/s: Measuring range; Unusable rangeNull zone30 mmDamping zone36 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 1 ms; Transmission rate (cycle time): CANopen (0 ... 65,535 ms),...
Product detailsAdd to RFQ
MAX48N-12V30BC0500 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 500 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-12V30BM0300 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 300 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-12V30AE1565 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 1,565 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-22C0DCB1650 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning, speed; Measuring rangePosition (F.S.)0 mm ... 1,650 mm 1)Speed0 … 1,000 mm/s: Measuring range; Unusable rangeNull zone30 mmDamping zone36 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 1 ms; Transmission rate (cycle time): CANopen (0 ... 65,535 ms),...
Product detailsAdd to RFQ
MAX48N-12V30K10500 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 500 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-12V30AM0250 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 250 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-22A10BE0220 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 220 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone36 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...
Product detailsAdd to RFQ
MAX48N-12V30ME0500 - Sick
Safety-related parameters: MTTFd: mean time to dangerous failure: 69 years (EN ISO 13849-1) 1) 2); Performance: Measured values: Positioning; Measuring rangePosition (F.S.)0 mm ... 500 mm 1): Measuring range; Unusable rangeNull zone30 mmDamping zone30 mm: Unusable range; Switch-on time: < 250 ms; Measuring frequency (internal): 2 ms; Transmission rate (cycle time): Constant analog output signal; Setpoint toleranceZero point and F.S.≤...