Magnetic-inductive volumetric flow meters

Magnetic-inductive volumetric flow meters

Items 1 - 6 of 6 from IFM ⍾ Last modified Oct 1, 2025

Magnetic-inductive volumetric flow meters ⍾ Page 1

Product detailsAdd to RFQ
SM9400 - Ifm
Magnetic-inductive flow meter; Operating voltage [V] : 18...32 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs :...
Product detailsAdd to RFQ
SM8500 - Ifm
Magnetic-inductive flow meter; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs : 2; Output...
Product detailsAdd to RFQ
SM8400 - Ifm
Magnetic-inductive flow meter; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs : 2; Output...
Product detailsAdd to RFQ
SM8601 - Ifm
Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs : 2; Output function : normally...
Product detailsAdd to RFQ
SM9500 - Ifm
Magnetic-inductive flow meter; Operating voltage [V] : 18...32 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs :...
Product detailsAdd to RFQ
SM9601 - Ifm
Operating voltage [V] : 18...32 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs : 2; Output function...