[siemens_summary]
[catalog_children]
[catalog_search_products]
Mid range distance sensors

Mid range distance sensors

Items 25 - 36 of 102 from SICK ⍾ Last modified Sep 3, 2025

Mid range distance sensors ⍾ Page 3

Product detailsAdd to RFQ
DT50-N1114 - Sick
Dx50, DT50. Measuring range: 200 mm ... 10,000 mm, 90 % remision, 200 mm ... 4,000 mm, 6 % remission, 200 mm ... 6,500 mm, 18 % remission. Response time: 20 ms / 30 ms. Repeatability: 5 mm / 2.5 mm. Light source: Laser, red. Laser protection class: 2 (EN 60825-1). Multifunctional input: 1 x NPN.
Product detailsAdd to RFQ
DT50-N1123 - Sick
Dx50, DT50. Measuring range: 200 mm ... 10,000 mm, 90 % remision, 200 mm ... 2,500 mm, 6 % remission, 200 mm ... 5,000 mm, 18 % remission. Response time: 20 ms / 30 ms. Repeatability: 5 mm / 2.5 mm. Light source: Laser, red. Laser protection class: 1 (EN 60825-1). Multifunctional input: 1 x NPN.
Product detailsAdd to RFQ
DT50-N2123 - Sick
Dx50, DT50 Hi. Measuring range: 200 mm ... 13,000 mm, 90 % remision, 200 mm ... 3,400 mm, 6 % remission, 200 mm ... 5,800 mm, 18 % remission. Response time: 15 ms / 30 ms / 80 ms. Repeatability: 3 mm / 2 mm / 1 mm. Light source: Laser, red. Laser protection class: 1 (EN 60825-1). Multifunctional input:...
Product detailsAdd to RFQ
DT50-N2113 - Sick
Dx50, DT50 Hi. Measuring range: 200 mm ... 20,000 mm, 90 % remision, 200 mm ... 5,000 mm, 6 % remission, 200 mm ... 8,500 mm, 18 % remission. Response time: 15 ms / 30 ms / 80 ms. Repeatability: 3 mm / 2 mm / 1 mm. Light source: Laser, red. Laser protection class: 2 (EN 60825-1). Multifunctional input:...
Product detailsAdd to RFQ
DT50-N1124 - Sick
Dx50, DT50. Measuring range: 200 mm ... 10,000 mm, 90 % remision, 200 mm ... 2,500 mm, 6 % remission, 200 mm ... 5,000 mm, 18 % remission. Response time: 20 ms / 30 ms. Repeatability: 5 mm / 2.5 mm. Light source: Laser, red. Laser protection class: 1 (EN 60825-1). Multifunctional input: 1 x NPN.
Product detailsAdd to RFQ
DT50-N1113 - Sick
Dx50, DT50. Measuring range: 200 mm ... 10,000 mm, 90 % remision, 200 mm ... 4,000 mm, 6 % remission, 200 mm ... 6,500 mm, 18 % remission. Response time: 20 ms / 30 ms. Repeatability: 5 mm / 2.5 mm. Light source: Laser, red. Laser protection class: 2 (EN 60825-1). Multifunctional input: 1 x NPN.
Product detailsAdd to RFQ
DT50-P1113 - Sick
Dx50, DT50. Measuring range: 200 mm ... 10,000 mm, 90 % remision, 200 mm ... 4,000 mm, 6 % remission, 200 mm ... 6,500 mm, 18 % remission. Response time: 20 ms / 30 ms. Repeatability: 5 mm / 2.5 mm. Light source: Laser, red. Laser protection class: 2 (EN 60825-1). Multifunctional input: 1 x PNP.
Product detailsAdd to RFQ
DT35-B15851 - Sick
Dx35, DT35, IO-Link. Measuring range: 50 mm ... 12,000 mm, 90 % remision, 50 mm ... 3,100 mm, 6 % remission, 50 mm ... 5,300 mm, 18 % remission. Response time: 2.5 ms / 6.5 ms / 12.5 ms / 24.5 ms / 96.5 ms. Repeatability: 0,5 mm ... 5 mm. Light source: Laser, infrared.
Product detailsAdd to RFQ
DT35-B15251 - Sick
Dx35, DT35, IO-Link. Measuring range: 50 mm ... 12,000 mm, 90 % remision, 50 mm ... 3,100 mm, 6 % remission, 50 mm ... 5,300 mm, 18 % remission. Response time: 2.5 ms / 6.5 ms / 12.5 ms / 24.5 ms / 96.5 ms. Repeatability: 0,5 mm ... 5 mm. Light source: Laser, red.
Product detailsAdd to RFQ
DT35-B15551 - Sick
Dx35, DT35, IO-Link. Measuring range: 50 mm ... 12,000 mm, 90 % remision, 50 mm ... 3,100 mm, 6 % remission, 50 mm ... 5,300 mm, 18 % remission. Response time: 4.5 ms / 12.5 ms / 24.5 ms / 48.5 ms / 192.5 ms. Repeatability: 0,5 mm ... 5 mm. Light source: Laser, red.
Product detailsAdd to RFQ
DS60-P51111S01 - Sick
Dx60, DS60. Measuring range: 80 mm ... 3,300 mm, 6 % remission, 80 mm ... 5,700 mm, 18 % remission, 80 mm ... 6,000 mm, 90 % remision. Response time: 100 ms. Light source: Laser, infrared. Laser protection class: 1 (EN 60825-1). Switching output (max. output current): 2x PNP (100 mA).
Product detailsAdd to RFQ
DS60-P51111 - Sick
Dx60, DS60. Measuring range: 80 mm ... 2,600 mm, 6 % remission, 80 mm ... 5,000 mm, 18 % remission, 80 mm ... 6,000 mm, 90 % remision. Response time: 50 ms. Light source: Laser, infrared. Laser protection class: 1 (EN 60825-1). Switching output (max. output current): 2x PNP (100 mA).