Position sensors ⍾ Page 218

Product detailsAdd to RFQ
I22002 - Ifm
Inductive area sensor; Frequency AC [Hz] : 47...63; Operating voltage [V] : 90...250 AC; Protection class : II; Reverse polarity protection : no; Output function : normally closed; Max. voltage drop switching output AC [V] : 11; Minimum load current [mA] : 15; Max. leakage current [mA] : 6; Permanent current rating of switching output AC [mA] : 200; (250...
Product detailsAdd to RFQ
I35001 - Ifm
Inductive sensor; Operating voltage [V] : 10...36 DC; Protection class : III; Reverse polarity protection : yes; Electrical design : PNP/NPN; Output function : normally open; Max. voltage drop switching output DC [V] : 4.7; Minimum load current [mA] : 4; Max. leakage current [mA] : 0.8; Permanent current rating of switching output DC [mA] : 100; Switching frequency DC...
Product detailsAdd to RFQ
GG711S - Ifm
Fail-safe inductive sensor; Operating voltage [V] : 19.2...30 DC; Rated insulation voltage [V] : 30; Protection class : III; Reverse polarity protection : yes; Max. power-on delay time [ms] : 1000; Electrical design : PNP; Output function : 2 x OSSD (A1 and A2); Max. voltage drop switching output DC [V] : 2.5; (30 mA); Permanent current rating of switching...
Product detailsAdd to RFQ
GI505S - Ifm
Fail-safe inductive sensor; Operating voltage [V] : 19.2...30 DC; Protection class : III; Reverse polarity protection : yes; Max. power-on delay time [ms] : 5000; Max. input capacitance Ci_max [nF] : 2; Output function : clock signal; Output data : Interface type B; Short-circuit protection : yes; Max. capacitive load CL_max [nF] : 20; Enable zone [mm] : 6...12; Safe...
Product detailsAdd to RFQ
GG507S - Ifm
Fail-safe inductive sensor; Operating voltage [V] : 19.2...30 DC; Protection class : III; Reverse polarity protection : yes; Max. power-on delay time [ms] : 5000; Max. input capacitance Ci_max [nF] : 2; Output function : clock signal; Output data : Interface type B; Short-circuit protection : yes; Max. capacitive load CL_max [nF] : 20; Enable zone [mm] : 1...4; Safe...
Product detailsAdd to RFQ
GI506S - Ifm
Fail-safe inductive sensor; Operating voltage [V] : 19.2...30 DC; Protection class : III; Reverse polarity protection : yes; Max. power-on delay time [ms] : 5000; Max. input capacitance Ci_max [nF] : 2; Output function : clock signal; Output data : Interface type B; Short-circuit protection : yes; Max. capacitive load CL_max [nF] : 20; Enable zone [mm] : 6...12; Safe...
Product detailsAdd to RFQ
GG712S - Ifm
Fail-safe inductive sensor; Operating voltage [V] : 19.2...30 DC; Rated insulation voltage [V] : 30; Protection class : III; Reverse polarity protection : yes; Max. power-on delay time [ms] : 1000; Electrical design : PNP; Output function : 2 x OSSD (A1 and A2); Max. voltage drop switching output DC [V] : 2.5; (30 mA); Permanent current rating of switching...
Product detailsAdd to RFQ
GG505S - Ifm
Fail-safe inductive sensor; Operating voltage [V] : 19.2...30 DC; Protection class : III; Reverse polarity protection : yes; Max. power-on delay time [ms] : 5000; Max. input capacitance Ci_max [nF] : 2; Output function : clock signal; Output data : Interface type B; Short-circuit protection : yes; Max. capacitive load CL_max [nF] : 20; Enable zone [mm] : 3...6; Safe...
Product detailsAdd to RFQ
GI711S - Ifm
Fail-safe inductive sensor; Operating voltage [V] : 19.2...30 DC; Rated insulation voltage [V] : 30; Protection class : III; Reverse polarity protection : yes; Max. power-on delay time [ms] : 1000; Electrical design : PNP; Output function : 2 x OSSD (A1 and A2); Max. voltage drop switching output DC [V] : 2.5; (30 mA); Permanent current rating of switching...
Product detailsAdd to RFQ
GF711S - Ifm
Fail-safe inductive sensor; Operating voltage [V] : 19.2...30 DC; Rated insulation voltage [V] : 30; Protection class : III; Reverse polarity protection : yes; Max. power-on delay time [ms] : 1000; Electrical design : PNP; Output function : 2 x OSSD (A1 and A2); Max. voltage drop switching output DC [V] : 2.5; (30 mA); Permanent current rating of switching...
Product detailsAdd to RFQ
GI712S - Ifm
Fail-safe inductive sensor; Operating voltage [V] : 19.2...30 DC; Rated insulation voltage [V] : 30; Protection class : III; Reverse polarity protection : yes; Max. power-on delay time [ms] : 1000; Electrical design : PNP; Output function : 2 x OSSD (A1 and A2); Max. voltage drop switching output DC [V] : 2.5; (30 mA); Permanent current rating of switching...
Product detailsAdd to RFQ
GG714S - Ifm
Fail-safe inductive sensor; Operating voltage [V] : 19.2...30 DC; Rated insulation voltage [V] : 30; Protection class : III; Reverse polarity protection : yes; Max. power-on delay time [ms] : 1000; Electrical design : PNP; Output function : 2 x OSSD (A1 and A2); Max. voltage drop switching output DC [V] : 2.5; (30 mA); Permanent current rating of switching...