[siemens_summary]
[catalog_children]
[catalog_search_products]

Pressure transmiters DSIII ⍾ Page 100

Product detailsAdd to RFQ
7MF4033-1EA00-1AA6-Z Y01 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,63 ... 63 bar g (9.14 ... 914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing Standard design None explosion protection Electric connection and...
Product detailsAdd to RFQ
7MF4033-1EA00-1AA6 - Siemens
SITRANS P DS III / P410, HART,4-20 MA TRANSMITTER FOR PRESSURE MEASURING CELL FILLING SILICONE OIL, NORMAL CLEANING SPAN: 0,63 ... 63 BAR G (9.14 ... 914 PSI G), OVERLOAD LIMIT 100 BAR DIAPHRAGM STAINLESS STEEL, MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: CONNECTION SHANK G1/2 B TO EN 837-1 DIE-CAST ALUMINIUM HOUSING STANDARD DESIGN NONE EXPLOSION PROTECTION ELECTRIC CONNECTION AND...
Product detailsAdd to RFQ
7MF4033-1EA00-1AA1-Z A01 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,63 ... 63 bar g (9.14 ... 914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing Standard design None explosion protection Electric connection and...
Product detailsAdd to RFQ
7MF4033-1EA00-1AA0-Z A01 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,63 ... 63 bar g (9.14 ... 914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing Standard design None explosion protection Electric connection and...
Product detailsAdd to RFQ
7MF4033-1EA00-1AA1-Z A02 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,63 ... 63 bar g (9.14 ... 914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing Standard design None explosion protection Electric connection and...
Product detailsAdd to RFQ
7MF4033-1DY10-1DB7-Z B11 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,16 ... 16 bar g (2.32 ... 232 psi g), overload limit 32 bar Version for diaphragm pressure controller. Consider additional delivery time for Remote seal. Remote seals must be ordered with an additional article no. Process connection: female thread 1/2-14...
Product detailsAdd to RFQ
7MF4033-1DY00-2AB7-Z Y15 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,16 ... 16 bar g (2.32 ... 232 psi g), overload limit 32 bar Design for remote seals. note: please add the delivery time of the remote seal! Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing International...
Product detailsAdd to RFQ
7MF4033-1DY00-2AB6-Z Y01 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,16 ... 16 bar g (2.32 ... 232 psi g), overload limit 32 bar Design for remote seals. note: please add the delivery time of the remote seal! Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing International...
Product detailsAdd to RFQ
7MF4033-1EA00-1AA1-Z A02 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,63 ... 63 bar g (9.14 ... 914 psi g), overload limit 100 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing Standard design None explosion protection Electric connection and...
Product detailsAdd to RFQ
7MF4033-1DY00-1AB6 - Siemens
SITRANS P DS III, HART,4-20 MA TRANSMITTER FOR PRESSURE MEASURING CELL FILLING SILICONE OIL, NORMAL CLEANING SPAN: 0,16 ... 16 BAR G (2.32 ... 232 PSI G), OVERLOAD LIMIT 32 BAR DESIGN FOR REMOTE SEALS. NOTE: PLEASE ADD THE DELIVERY TIME OF THE REMOTE SEAL! PROCESS CONNECTION: CONNECTION SHANK G1/2 B TO EN 837-1 DIE-CAST ALUMINIUM HOUSING STANDARD DESIGN NONE...
Product detailsAdd to RFQ
7MF4033-1DY00-2AC6-Z A01-Y01 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure
Product detailsAdd to RFQ
7MF4033-1DY00-2DB6-Z A01 - Siemens
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,16 ... 16 bar g (2.32 ... 232 psi g), overload limit 32 bar Version for diaphragm pressure controller. Consider additional delivery time for Remote seal. Remote seals must be ordered with an additional article no. Process connection: connection shank G1/2...