[siemens_summary]
[catalog_children]
[catalog_search_products]

Safety relays ⍾ Page 5

1345679
Product detailsAdd to RFQ
PSR-MS25-1NO-1DO-24DC-SC - Phoenix Contact
Safety relays - PSR-MS25-1NO-1DO-24DC-SC - 2904951; Safety relay for emergency stop and safety doors up to SILCL 1, Cat. 1, PL c, depending on the application up to SILCL 3, Cat. 4, PL e, 1-channel operation, manual, monitored start, 1 enabling current path, US = 24 V DC, fixed screw terminal block
Product detailsAdd to RFQ
PSR-MS55-1NO-1DO-24DC-SC - Phoenix Contact
Safety relays - PSR-MS55-1NO-1DO-24DC-SC - 2904957; Safety relay for monitoring non-equivalent signal generators up to SILCL 3, Cat. 4, PL e, 2-channel, non-equivalent operation, manual, monitored start, 1 enabling current path, US = 24 V DC, fixed screw terminal block
Product detailsAdd to RFQ
PSR-MS20-1NO-1DO-24DC-SC - Phoenix Contact
Safety relays - PSR-MS20-1NO-1DO-24DC-SC - 2904950; Safety relay for emergency stop and safety doors up to SILCL 1, Cat. 1, PL c, depending on the application up to SILCL 3, Cat. 4, PL e, 1-channel operation, automatic start, 1 enabling current path, US = 24 V DC, fixed screw terminal block
Product detailsAdd to RFQ
PSR-MS45-1NO-1DO-24DC-SC - Phoenix Contact
Safety relays - PSR-MS45-1NO-1DO-24DC-SC - 2904955; Safety relay for emergency stop and safety doors up to SILCL 3, Cat. 4, PL e, 1 or 2-channel operation, manual, monitored start, 1 enabling current path, US = 24 V DC, fixed screw terminal block
Product detailsAdd to RFQ
PSR-MS40-1NO-1DO-24DC-SC - Phoenix Contact
Safety relays - PSR-MS40-1NO-1DO-24DC-SC - 2904954; Safety relay for emergency stop and safety doors up to SILCL 3, Cat. 4, PL e, 1 or 2-channel operation, automatic start, 1 enabling current path, US = 24 V DC, fixed screw terminal block
Product detailsAdd to RFQ
PSR-MS50-1NO-1DO-24DC-SC - Phoenix Contact
Safety relays - PSR-MS50-1NO-1DO-24DC-SC - 2904956; Safety relay for monitoring non-equivalent signal generators up to SILCL 3, Cat. 4, PL e, 2-channel, non-equivalent operation, automatic start, 1 enabling current path, US = 24 V DC, fixed screw terminal block
Product detailsAdd to RFQ
PSR-MS35-1NO-24DC-SC - Phoenix Contact
Safety relays - PSR-MS35-1NO-24DC-SC - 2904953; Safety relay for emergency stop and safety doors up to SILCL 3, Cat. 4, PL e, 1 or 2-channel operation, manual, monitored start, cross-circuit detection, 1 enabling current path, US = 24 V DC, fixed screw terminal block
Product detailsAdd to RFQ
PSR-SPP-24DC/URML4/3X1/1X2/B - Phoenix Contact
Extension module - PSR-SPP-24DC/URML4/3X1/1X2/B - 2903584; Single or two-channel contact extension for OSSD signals (e.g., light grid), 3 N/O contacts, 1 N/C contact, up to Cat. 4 PL e according to EN ISO 13849, SIL 3 according to EN 62061, plug-in spring-cage terminal block, width: 22.5 mm
Product detailsAdd to RFQ
PSR-SCP-24DC/URML4/3X1/1X2/B - Phoenix Contact
Extension module - PSR-SCP-24DC/URML4/3X1/1X2/B - 2903583; Single or two-channel contact extension for OSSD signals (e.g., light grid), 3 N/O contacts, 1 N/C contact, up to Cat. 4 PL e according to EN ISO 13849, SIL 3 according to EN 62061, plug-in screw terminal blocks, width: 22.5 mm
Product detailsAdd to RFQ
PSR-SCP-230AC/ESAM2/3X1/1X2/B - Phoenix Contact
Safety relays - PSR-SCP-230AC/ESAM2/3X1/1X2/B - 2901430; Safety relay for emergency stop and safety door up to SIL 1, SIL CL 1, Cat. 1, PL c, depending on the application up to SIL 3, SIL CL 3, Cat. 4, PL e, single-channel operation, 3 enabling current paths, nominal input voltage of 230 V AC/DC, plug-in screw terminal blocks
Product detailsAdd to RFQ
PSR-SPP-230UC/ESAM4/3X1/1X2/B - Phoenix Contact
Safety relays - PSR-SPP-230UC/ESAM4/3X1/1X2/B - 2901429; Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e according to EN ISO 13849, 1 or 2-channel operation, 3 enabling current paths, nominal input voltage: 230 V AC/DC, plug-in spring-cage terminal block
Product detailsAdd to RFQ
PSR-SPP-230AC/ESAM2/3X1/1X2/B - Phoenix Contact
Safety relays - PSR-SPP-230AC/ESAM2/3X1/1X2/B - 2901431; Safety relay for emergency stop and safety door up to SIL 1, SIL CL 1, Cat. 1, PL c, depending on the application up to SIL 3, SIL CL 3, Cat. 4, PL e, single-channel operation, 3 enabling current paths, nominal input voltage of 230 V AC/DC, plug-in spring-cage terminal block