[siemens_summary]
[catalog_children]
[catalog_search_products]

Safety Switches ⍾ Page 1

Product detailsAdd to RFQ
TR4-SFU02CB - Sick
Features: System part: Sensor and actuator; Sensor principle: Transponder; Number of safe outputs: 2; Safe switch on distance Sao: 15 mm; Safe switch off distance Sar: 35 mm; Active sensor surfaces: 2; Actuation directions: 5; Retaining force: ≤ 10 N; Boundary area indication: ✔; Coding: Uniquely coded; Safety-related parameters: Safety integrity level: SIL3 (IEC 61508)SILCL3 (EN 62061); Category: Category 4...
Product detailsAdd to RFQ
TR4-SFU10P - Sick
TR4 Direct Sensor & actuator. Product family: TR4 Direct. System part: Sensor & actuator. Connection type: Cable. Cable length: 10 m.
Product detailsAdd to RFQ
TR4-SFU10PB - Sick
Features: System part: Sensor and actuator; Sensor principle: Transponder; Number of safe outputs: 2; Safe switch on distance Sao: 15 mm; Safe switch off distance Sar: 35 mm; Active sensor surfaces: 2; Actuation directions: 5; Retaining force: ≤ 10 N; Boundary area indication: ✔; Coding: Uniquely coded; Safety-related parameters: Safety integrity level: SIL3 (IEC 61508)SILCL3 (EN 62061); Category: Category 4...
Product detailsAdd to RFQ
TR4-SFU03P - Sick
TR4 Direct Sensor & actuator. Product family: TR4 Direct. System part: Sensor & actuator. Connection type: Cable. Cable length: 3 m.
Product detailsAdd to RFQ
TR4-SFU03PB - Sick
Features: System part: Sensor and actuator; Sensor principle: Transponder; Number of safe outputs: 2; Safe switch on distance Sao: 15 mm; Safe switch off distance Sar: 35 mm; Active sensor surfaces: 2; Actuation directions: 5; Retaining force: ≤ 10 N; Boundary area indication: ✔; Coding: Uniquely coded; Safety-related parameters: Safety integrity level: SIL3 (IEC 61508)SILCL3 (EN 62061); Category: Category 4...
Product detailsAdd to RFQ
TR4-SFU02C - Sick
Features: System part: Sensor and actuator; Sensor principle: Transponder; Number of safe outputs: 2; Safe switch on distance Sao: 15 mm; Safe switch off distance Sar: 35 mm; Active sensor surfaces: 2; Actuation directions: 5; Magnetic retaining force: ✔; Boundary area indication: ✔; Coding: Uniquely coded; Safety-related parameters: Safety integrity level: SIL3 (IEC 61508), SILCL3 (EN 62061); Category: Category 4...
Product detailsAdd to RFQ
TR4-SFM10P - Sick
TR4 Direct Sensor & actuator. Product family: TR4 Direct. System part: Sensor & actuator. Connection type: Cable. Cable length: 10 m.
Product detailsAdd to RFQ
TR4-SFU01CB - Sick
Features: System part: Sensor and actuator; Sensor principle: Transponder; Number of safe outputs: 2; Safe switch on distance Sao: 15 mm; Safe switch off distance Sar: 35 mm; Active sensor surfaces: 2; Actuation directions: 5; Retaining force: ≤ 10 N; Boundary area indication: ✔; Coding: Uniquely coded; Safety-related parameters: Safety integrity level: SIL3 (IEC 61508)SILCL3 (EN 62061); Category: Category 4...
Product detailsAdd to RFQ
TR4-SFU01C - Sick
TR4 Direct Sensor & actuator. Product family: TR4 Direct. System part: Sensor & actuator. Connection type: Cable with plug M12, 8-pin. Cable length: 0.2 m.
Product detailsAdd to RFQ
TR4-SFM10PB - Sick
Features: System part: Sensor and actuator; Sensor principle: Transponder; Number of safe outputs: 2; Safe switch on distance Sao: 15 mm; Safe switch off distance Sar: 35 mm; Active sensor surfaces: 2; Actuation directions: 5; Retaining force: ≤ 10 N; Boundary area indication: ✔; Coding: Universally coded; Safety-related parameters: Safety integrity level: SIL3 (IEC 61508)SILCL3 (EN 62061); Category: Category 4...
Product detailsAdd to RFQ
TR4-SEU10PB - Sick
Features: System part: Sensor and actuator; Sensor principle: Transponder; Number of safe outputs: 2; Safe switch on distance Sao: 15 mm; Safe switch off distance Sar: 35 mm; Active sensor surfaces: 2; Actuation directions: 5; Boundary area indication: ✔; Coding: Uniquely coded; Safety-related parameters: Safety integrity level: SIL3 (IEC 61508)SILCL3 (EN 62061); Category: Category 4 (EN ISO 13849); Performance level:...
Product detailsAdd to RFQ
TR4-SFM02C - Sick
Features: System part: Sensor and actuator; Sensor principle: Transponder; Number of safe outputs: 2; Safe switch on distance Sao: 15 mm; Safe switch off distance Sar: 35 mm; Active sensor surfaces: 2; Actuation directions: 5; Retaining force: ≤ 10 N; Boundary area indication: ✔; Coding: Universally coded; Safety-related parameters: Safety integrity level: SIL3 (IEC 61508), SILCL3 (EN 62061); Category: Category...