[siemens_summary]
[catalog_children]
[catalog_search_products]

Sensors for motion control ⍾ Page 1

Product detailsAdd to RFQ
SR5906 - Ifm
Control monitor for flow sensors; Frequency AC [Hz] : 47...63; Operating voltage tolerance [%] : -15...10; Operating voltage [V] : 90...240 AC; Max. power consumption [VA] : 3.5; Protection class : II; Reverse polarity protection : no; Power-on delay time [s] : 10; Number of channels : 1; Electrical design : relay; Contact rating : 3 A (250 V AC...
Product detailsAdd to RFQ
SR5900 - Ifm
Control monitor for flow sensors; Operating voltage [V] : 19...36 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 10; Number of channels : 1; Electrical design : PNP; Max. voltage drop switching output DC [V] : 2.5; Permanent current rating of switching output DC [mA] : 250; Switching function flow monitoring : output...
Product detailsAdd to RFQ
SR307A - Ifm
Control monitor for flow sensors; Operating voltage tolerance [%] : -15...15; Operating voltage [V] : 24 DC; Reverse polarity protection : no; Power-on delay time [s] : 10; Number of channels : 1; Performance in case of a fault : Relay de-energised in case of the following faults: wire break, reverse polarity or short circuit of the sensor cable, undervoltage,...
Product detailsAdd to RFQ
SN2303 - Ifm
Control monitor for flow sensors; Frequency AC [Hz] : 47...63; Operating voltage tolerance [%] : -10...10; Operating voltage [V] : 0,7) ; 0,2 A (250 V DC); 4 A (24 V DC); Switching function flow monitoring : relay energised when flow is present; Switching function wire break monitoring : relay de-energised in case of wire break; Short-circuit proof : no;...
Product detailsAdd to RFQ
SR2301 - Ifm
Control monitor for flow sensors; Operating voltage tolerance [%] : -10...10; Operating voltage [V] : 24 DC; Reverse polarity protection : no; Power-on delay time [s] : 30; Number of channels : 1; Electrical design : relay; Contact rating : 4 A (250 V AC cos phi > 0,7) ; 0,2 A (250 V DC); 4 A (24 V DC);...
Product detailsAdd to RFQ
SN2304 - Ifm
Control monitor for flow sensors; Frequency AC [Hz] : 47...63; Operating voltage tolerance [%] : -10...10; Operating voltage [V] : 0,7) ; 0,2 A (250 V DC); 4 A (24 V DC); Switching function flow monitoring : relay energised when flow is present; Switching function wire break monitoring : relay de-energised in case of wire break; Short-circuit proof : no;...
Product detailsAdd to RFQ
SR0150 - Ifm
Control monitor for flow sensors; Operating voltage tolerance [%] : -20...10; Operating voltage [V] : 24 DC; Protection class : III; Reverse polarity protection : no; Power-on delay time [s] : 10...80; (adjustable (fixed-value resistors terminals 22-23)); Number of channels : 1; Performance in case of a fault : In case of undervoltage all relays are de-energised; the LED "LOW...
Product detailsAdd to RFQ
SR0127 - Ifm
Control monitor for flow sensors; Operating voltage tolerance [%] : -10...10; Operating voltage [V] : 24 DC; Reverse polarity protection : yes; Power-on delay time [s] : < 20; Number of channels : 1; Electrical design : PNP; Permanent current rating of switching output DC [mA] : 400; Switching function flow monitoring : output switches ON when flow is present;...
Product detailsAdd to RFQ
SR0151 - Ifm
Control monitor for flow sensors; Operating voltage tolerance [%] : -20...10; Operating voltage [V] : 24 DC; Protection class : III; Reverse polarity protection : no; Power-on delay time [s] : 10...80; (adjustable (fixed-value resistors terminals 22-23)); Number of channels : 1; Performance in case of a fault : In case of undervoltage all relays are de-energised; the LED "LOW...
Product detailsAdd to RFQ
SN0500 - Ifm
Control monitor for flow sensors; Frequency AC [Hz] : 47...63; Operating voltage tolerance [%] : -5...10; Operating voltage [V] : 90...240 AC; Max. power consumption [VA] : 4; Protection class : II; Reverse polarity protection : no; Power-on delay time [s] : 10...80; (adjustable (fixed-value resistors terminals 22-23)); Number of channels : 1; Performance in case of a fault :...
Product detailsAdd to RFQ
SN0152 - Ifm
Control monitor for flow sensors; Frequency AC [Hz] : 47...63; Operating voltage tolerance [%] : -5...10; Operating voltage [V] : 90...240 AC; Max. power consumption [VA] : 4; Protection class : II; Reverse polarity protection : no; Power-on delay time [s] : 10...80; (adjustable (fixed-value resistors terminals 22-23)); Number of channels : 1; Performance in case of a fault :...
Product detailsAdd to RFQ
SR0153 - Ifm
Control monitor for flow sensors; Operating voltage tolerance [%] : -10...10; Operating voltage [V] : 24 DC; Protection class : III; Reverse polarity protection : no; Power-on delay time [s] : 10...80; (adjustable (fixed-value resistors terminals 22-23)); Number of channels : 1; Performance in case of a fault : In case of undervoltage all relays are de-energised; the LED "LOW...