Siemens

[siemens_summary]
[catalog_children]
[catalog_search_products]

Siemens ⍾ Page 10528

Product detailsAdd to RFQ
3WL1232-2..33-.... - Siemens
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE II, IEC IN=3200A TO 690V, AC50/60HZ ICU=66KA AT 500V FRNT.CONN. TOP/BOT. SINGLE-HOLE
Product detailsAdd to RFQ
3WL1225-4CB65-4AN2 - Siemens
Draw-out circuit breaker Without guide frame 3-pole, Size 2, IEC In=2500 A to 690 V, 50/60 Hz AC Icu=100 kA at 500 V Rear horizontal connection Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC...
Product detailsAdd to RFQ
3WL1225-4CB77-4GA4-Z A15 - Siemens
Draw-out circuit breaker with slide-in module frame 4-pole, Size 2, IEC In=2500 A to 690 V, 50/60 Hz AC Icu=100 kA at 500 V Rear vertical connection Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V...
Product detailsAdd to RFQ
3WL1225-4CB65-4AN2-Z A05 - Siemens
Draw-out circuit breaker Without guide frame 3-pole, Size 2, IEC In=2500 A to 690 V, 50/60 Hz AC Icu=100 kA at 500 V Rear horizontal connection Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC...
Product detailsAdd to RFQ
3WL1232-2..32-.... - Siemens
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE II, IEC IN=3200A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
Product detailsAdd to RFQ
3WL1225-4EG46-6AN2 - Siemens
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 4-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=100KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 45 LSIN PROT ADJUST. 0.4-1 IN WITH CUBICLE BUS AND EARTH FLT COMMUN./MEASURING FUNC./ ZSS OPTION MOT./MAN. OPER.MECHAN. W.STOR. DRIVE MOTOR DC 24-30 V REQUEST DC 24V WITHOUT 1ST SHUNT TRIP WITH 2ND AUX. RELEASE "R",...
Product detailsAdd to RFQ
3WL1225-4EG38-5FA4 - Siemens
Withdrawable circuit breaker with guide frame 3-pole, size II, IEC In=2500A to 690V, AC50/60Hz Icu=100kA at 500V w. connection flange Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110...
Product detailsAdd to RFQ
3WL1225-4EG36-4GG4-Z C22 - Siemens
Withdrawable circuit breaker with guide frame 3-pole, size II, IEC In=2500A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protection adjustable 0.4-1 in with cubicle bus and Ground fault protection Opt.: Comm./measuring func./ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230...
Product detailsAdd to RFQ
3WL1225-4DG46-1AA2 - Siemens
Withdrawable circuit breaker with guide frame 4-pole, size II, IEC In=2500A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC
Product detailsAdd to RFQ
3WL1225-4EB35-1AA4 - Siemens
WITHDRAWABLE CIRCUIT BREAKER WITHOUT GUIDE FRAME 3-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=100KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 45 LSIN PROT. ADJUST.B. 0.4-1 IN WITH CUBICLE BUS COMMUN./MEASURING FUNCT../ W. MAN. OPER. MECHAN. & STORAGE WITH MECHANICAL REQUEST WITHOUT 1ST SHUNT TRIP WITHOUT 2ND SHUNT TRIP 4NO+4NC
Product detailsAdd to RFQ
3WL1225-4EB36-5BA4-Z B25 - Siemens
Withdrawable circuit breaker with guide frame 3-pole, size II, IEC In=2500A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 in with cubicle bus Opt.: Comm. /measuring func./ground fault/ ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V...
Product detailsAdd to RFQ
3WL1225-4EB36-4GG4 - Siemens
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 3-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=100KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 45 LSIN PROT. ADJUST.B. 0.4-1 IN WITH CUBICLE BUS COMMUN./MEASURING FUNCT../ MOT./MAN. OPER.MECHAN. W.STOR. DRIVE MOTOR AC 50/60HZ 208-240V BZW DC 220-250V REQU. AC 50/60HZ 230V, DC 220V WITH 1ST AUXILIARY RELEASE SHUNT TRIP"F", F1 AC50/60HZ...