[siemens_summary]
[catalog_children]
[catalog_search_products]
Signal conditioners with functional safety

Signal conditioners with functional safety

Items 1 - 12 of 53 from Phoenix Contact ⍾ Last modified Aug 31, 2025

Signal conditioners with functional safety ⍾ Page 1

Product detailsAdd to RFQ
MACX MCR-SL-RPSSI-2I-SP - Phoenix Contact
Repeater power supply - MACX MCR-SL-RPSSI-2I-SP - 2924838; Measuring transducer repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4…20 mA electrically isolated signals from the field to two loads. 4-way electrical isolation, Push-in connection, SIL, PL.
Product detailsAdd to RFQ
MACX MCR-CJC - Phoenix Contact
Plug - MACX MCR-CJC - 2924993; Plug for cold junction compensation for thermocouples, for safe switching of limit values, in combination with MACX ...-T-UI... temperature transducers.
Product detailsAdd to RFQ
MACX MCR-SL-NAM-2RO-SP - Phoenix Contact
Isolation amplifier - MACX MCR-SL-NAM-2RO-SP - 2924265; NAMUR signal conditioner for operating proximity sensors and switches. The signals are transferred to the control level using 2 isolated relay outputs (N/O contact). Line fault detection (LFD), 3-way electrical isolation, SIL 2, Push-in connection.
Product detailsAdd to RFQ
MACX MCR-SL-NAM-R-SP - Phoenix Contact
Isolation amplifier - MACX MCR-SL-NAM-R-SP - 2924252; NAMUR isolation amplifier for operating proximity sensors and switches. The signals are transferred to the control level using relay output (PDT). Line fault detection (LFD), galvanic 3-way isolation, SIL 2, with push-in connection.
Product detailsAdd to RFQ
MACX MCR-SL-NAM-2T-SP - Phoenix Contact
Isolation amplifier - MACX MCR-SL-NAM-2T-SP - 2924278; NAMUR signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via 2 transistor outputs (passive). Line fault detection, 3-way electrical isolation, SIL 2, Push-in connection.
Product detailsAdd to RFQ
MACX MCR-SL-2NAM-T-SP - Phoenix Contact
Isolation amplifier - MACX MCR-SL-2NAM-T-SP - 2924281; NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via transistor outputs (passive). Line fault detection, 3-way electrical isolation, SIL 2, Push-in connection.
Product detailsAdd to RFQ
MACX MCR-SL-RPSSI-2I - Phoenix Contact
Repeater power supply - MACX MCR-SL-RPSSI-2I - 2924825; Measuring transducer repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4…20 mA electrically isolated signals from the field to two loads. 4-way electrical isolation, screw connection, SIL, PL.
Product detailsAdd to RFQ
MACX MCR-SL-TC-I-NC - Phoenix Contact
Temperature measuring transducer - MACX MCR-SL-TC-I-NC - 2924346; Temperature transducer, converts signals from thermocouples and linear mV sources into 0/4-20 mA signals. Freely programmable, 3-way electrical isolation, custom-configured.
Product detailsAdd to RFQ
MACX MCR-SL-RTD-I-SP-NC - Phoenix Contact
Temperature measuring transducer - MACX MCR-SL-RTD-I-SP-NC - 2924320; Temperature transducer, converts signals from resistance thermometers and resistors into 0/4 - 20 mA signals. Freely programmable, 3-way electrical isolation.
Product detailsAdd to RFQ
MACX MCR-SL-2NAM-RO-SP - Phoenix Contact
Isolation amplifier - MACX MCR-SL-2NAM-RO-SP - 2924294; NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transferred to the control level using relay outputs (N/O contact). Line fault detection, 3-way electrical isolation, SIL 2, Push-in connection.
Product detailsAdd to RFQ
MACX MCR-SL-2NAM-R-UP-SP - Phoenix Contact
Isolation amplifier - MACX MCR-SL-2NAM-R-UP-SP - 2924304; 2-channel NAMUR signal conditioner with wide range power supply for proximity sensors and switches. In terms of signal output, for each channel there is a relay with a changeover contact available. Line fault detection (LFD), 3-way isolation, Push-in connection, SIL 2.
Product detailsAdd to RFQ
MACX MCR-SL-RPSSI-I-SP - Phoenix Contact
Power/input isolating amplifier - MACX MCR-SL-RPSSI-I-SP - 2924207; Repeater power supply and input isolating amplifier, HART. Transfers supplied or active 0/4 - 20 mA signals to a load (active or passive). 3-way electrical isolation, SIL 2 according to IEC 61508.