[siemens_summary]
[catalog_children]
[catalog_search_products]
STR1

STR1

Items 1 - 12 of 74 from SICK ⍾ Last modified Sep 4, 2025

STR1 ⍾ Page 1

Product detailsAdd to RFQ
STR1-SAXU10P5 - Sick
Features: System part: Sensor; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Uniquely coded; Safety-related parameters: Safety...
Product detailsAdd to RFQ
STR1-SAXU0AC5 - Sick
Features: System part: Sensor; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Uniquely coded; Safety-related parameters: Safety...
Product detailsAdd to RFQ
STR1-SAXM10P5 - Sick
Features: System part: Sensor; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Universally coded; Safety-related parameters: Safety...
Product detailsAdd to RFQ
STR1-SAXM0AC8S02 - Sick
Features: System part: Sensor; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (switching behavior equivalent to actuator in the protected switch-on state); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding:...
Product detailsAdd to RFQ
STR1-SAXU03P8 - Sick
Features: System part: Sensor; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Uniquely coded; Safety-related parameters: Safety...
Product detailsAdd to RFQ
STR1-SASU10P8 - Sick
Features: System part: Sensor and actuator; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 10 mm (–30 °C ... +70 °C) 1); Safe switch off distance Sar: 25 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Uniquely coded; Safety-related parameters: Safety integrity level: SIL3...
Product detailsAdd to RFQ
STR1-SAXU03P5 - Sick
Features: System part: Sensor; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Uniquely coded; Safety-related parameters: Safety...
Product detailsAdd to RFQ
STR1-SAXU0AC8 - Sick
Features: System part: Sensor; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Uniquely coded; Safety-related parameters: Safety...
Product detailsAdd to RFQ
STR1-SAXM10P8 - Sick
Features: System part: Sensor; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Universally coded; Safety-related parameters: Safety...
Product detailsAdd to RFQ
STR1-SAXF03P5 - Sick
Features: System part: Sensor; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Permanently coded; Safety-related parameters: Safety...
Product detailsAdd to RFQ
STR1-SAXF03P8 - Sick
Features: System part: Sensor; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Permanently coded; Safety-related parameters: Safety...
Product detailsAdd to RFQ
STR1-SAXF10P8 - Sick
Features: System part: Sensor; Sensor principle: Transponder; Number of safe outputs: 2; Auxiliary contact (AUX): 1 (Switching behavior complementary to OSSDs); Safe switch on distance Sao: 14 mm (–10 ... +70 °C) 1)10 mm (–30 ... –10 °C) 1); Safe switch off distance Sar: 28 mm 1); Active sensor surfaces: 3; Actuation directions: 5; Coding: Permanently coded; Safety-related parameters: Safety...