[siemens_summary]
[catalog_children]
[catalog_search_products]
Switching amplifiers for Namur sensors

Switching amplifiers for Namur sensors

Items 1 - 9 of 9 from IFM ⍾ Last modified Oct 1, 2025

Switching amplifiers for Namur sensors ⍾ Page 1

Product detailsAdd to RFQ
N0033A - Ifm
Switching amplifiers for Namur sensors; Operating voltage tolerance [%] : -10...10; Operating voltage [V] : 0,7 // 40 V DC / 2 A; (ohmic resistance); Switching frequency AC [Hz] : 10; Ambient temperature [°C] : -20...60; Switching cycles mechanical : 10 million
Product detailsAdd to RFQ
N0530A - Ifm
Switching amplifiers for Namur sensors; Operating voltage tolerance [%] : -15...25; Operating voltage [V] : 24 DC; Number of channels : 1; Electrical design : relay; (1 changeover contact); Contact rating : 253 V AC / 2 A / cos phi > 0,7 // 40 V DC / 2 A; (ohmic resistance); Switching frequency DC [Hz] : 10; Ambient temperature...
Product detailsAdd to RFQ
N0032A - Ifm
Switching amplifiers for Namur sensors; Operating voltage tolerance [%] : -10...10; Operating voltage [V] : 0,7 // 40 V DC / 2 A; (ohmic resistance); Switching frequency AC [Hz] : 10; Ambient temperature [°C] : -20...60; Switching cycles mechanical : 10 million
Product detailsAdd to RFQ
N0533A - Ifm
Switching amplifiers for Namur sensors; Operating voltage tolerance [%] : -15...25; Operating voltage [V] : 24 DC; Number of channels : 2; Electrical design : relay; (per channel: 1 changeover contact parameterisable); Contact rating : 253 V AC / 2 A / cos phi > 0,7 // 40 V DC / 2 A; (ohmic resistance); Switching frequency DC [Hz] :...
Product detailsAdd to RFQ
N0534A - Ifm
Switching amplifiers for Namur sensors; Operating voltage tolerance [%] : -15...25; Operating voltage [V] : 24 DC; Number of channels : 2; Electrical design : PNP; Number of digital outputs : 2; Max. voltage drop switching output DC [V] : 3.5; Max. current load per output [mA] : 100; Switching frequency DC [Hz] : 5000; Short-circuit proof : yes; Ambient...
Product detailsAdd to RFQ
N0532A - Ifm
Switching amplifiers for Namur sensors; Operating voltage tolerance [%] : -15...25; Operating voltage [V] : 24 DC; Number of channels : 2; Electrical design : opto coupler; (bipolar; Voltage: max. 40 V DC); Number of digital outputs : 2; Max. voltage drop switching output DC [V] : 3; Max. current load per output [mA] : 100; Switching frequency DC [Hz]...
Product detailsAdd to RFQ
N0531A - Ifm
Switching amplifiers for Namur sensors; Operating voltage tolerance [%] : -15...25; Operating voltage [V] : 24 DC; Number of channels : 1; Electrical design : PNP; Number of digital outputs : 2; Max. voltage drop switching output DC [V] : 3.5; Max. current load per output [mA] : 100; Switching frequency DC [Hz] : 5000; Short-circuit proof : yes; Ambient...
Product detailsAdd to RFQ
N0031A - Ifm
Switching amplifiers for Namur sensors; Operating voltage tolerance [%] : -10...10; Operating voltage [V] : 0,7 // 40 V DC / 2 A; (ohmic resistance); Switching frequency AC [Hz] : 10; Ambient temperature [°C] : -20...60; Switching cycles mechanical : 10 million
Product detailsAdd to RFQ
N0030A - Ifm
Switching amplifiers for Namur sensors; Operating voltage tolerance [%] : -10...10; Operating voltage [V] : 0,7 // 40 V DC / 2 A; (ohmic resistance); Switching frequency AC [Hz] : 10; Ambient temperature [°C] : -20...60; Switching cycles mechanical : 10 million