[siemens_summary]
[catalog_children]
[catalog_search_products]
Use in hazardous areas

Use in hazardous areas

Items 1 - 8 of 8 from IFM ⍾ Last modified Oct 1, 2025

Use in hazardous areas ⍾ Page 1

Product detailsAdd to RFQ
KI505A - Ifm
Capacitive sensor; Operating voltage [V] : 10...30 DC; Protection class : III; Reverse polarity protection : yes; Measuring principle : capacitive; Electrical design : PNP; Output function : complementary; Max. voltage drop switching output DC [V] : 2.5; Max. leakage current [mA] : 0.1; Permanent current rating of switching output DC [mA] : 200; Switching frequency DC [Hz] : 10; Short-circuit...
Product detailsAdd to RFQ
KI5031 - Ifm
Capacitive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...15; Protection class : II; Measuring principle : capacitive; Electrical design : NAMUR;...
Product detailsAdd to RFQ
KI503A - Ifm
Capacitive sensor; Operating voltage [V] : 10...30 DC; Protection class : III; Reverse polarity protection : yes; Measuring principle : capacitive; Electrical design : PNP; Output function : complementary; Max. voltage drop switching output DC [V] : 2.5; Max. leakage current [mA] : 0.1; Permanent current rating of switching output DC [mA] : 200; Switching frequency DC [Hz] : 10; Short-circuit...
Product detailsAdd to RFQ
KI5030 - Ifm
Capacitive NAMUR sensor; Connection to switching amplifiers : yes; Switching amplifiers : connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW; Nominal voltage DC [V] : 8.2; (1kΩ); Supply voltage DC [V] : 7.5...15; Protection class : II; Measuring principle : capacitive; Electrical design : NAMUR;...
Product detailsAdd to RFQ
KI001A - Ifm
Capacitive sensor; Operating voltage [V] : 30...250 AC / 20...250 DC; Protection class : II; Reverse polarity protection : yes; Measuring principle : capacitive; Output function : normally open / normally closed; (selectable); Max. voltage drop switching output DC [V] : 8; Max. voltage drop switching output AC [V] : 10; Minimum load current [mA] : 5; Max. leakage current [mA]...
Product detailsAdd to RFQ
KI000A - Ifm
Capacitive sensor; Operating voltage [V] : 30...250 AC / 20...250 DC; Protection class : II; Reverse polarity protection : yes; Measuring principle : capacitive; Output function : normally open / normally closed; (selectable); Max. voltage drop switching output DC [V] : 8; Max. voltage drop switching output AC [V] : 10; Minimum load current [mA] : 5; Max. leakage current [mA]...
Product detailsAdd to RFQ
KD001A - Ifm
Capacitive sensor; Operating voltage [V] : 20...250 AC/DC; Protection class : II; Reverse polarity protection : no; Measuring principle : capacitive; Output function : normally open / normally closed; (selectable); Max. voltage drop switching output DC [V] : 8; Max. voltage drop switching output AC [V] : 10; Minimum load current [mA] : 5; Max. leakage current [mA] : 2.5 (250...
Product detailsAdd to RFQ
KD501A - Ifm
Capacitive sensor; Operating voltage [V] : 10...36 DC; Protection class : III; Reverse polarity protection : yes; Measuring principle : capacitive; Electrical design : PNP; Output function : normally open / normally closed; (selectable); Max. voltage drop switching output DC [V] : 2.5; Permanent current rating of switching output DC [mA] : 200; Switching frequency DC [Hz] : 10; Short-circuit proof...