SV7050 - Ifm
Vortex flow meter; Operating voltage [V] : 8...33 DC; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Power-on delay time [s] : < 2; Total number of outputs : 1; Output signal : analogue signal; Number of analogue outputs : 1; Analogue current output [mA] : 4...20; (water: Q [l/min] = 5,313 x (I - 4 mA); water-glycol: Q [l/min] = 5,313 x (I - 4 mA) - Qo see Figure 2); Max. load [Ω] : 5.5 to avoid cavitation; Materials : PA 6T; Materials (wetted parts) : ETFE; PA 6T; FKM; Tightening torque [Nm] : 12; Process connection : threaded connection G 1 DN20