Ifm – OY818S

SAFETY LIGHT CURTAINS Ifm – OY818S
Qty
Safety light curtain; Operating voltage tolerance [%] : 20; Operating voltage [V] : 24 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : < 18; Type of light : infrared light; Wave length [nm] : 950; Electrical design : PNP; Number of OSSD outputs : 2; Max. current load per OSSD output [mA] : 500; (24 V); Short-circuit protection : yes; Protected area height [mm] : 1060; Resolution (detection capacity d) [mm] : 20; Protection area width (low light intensity) [m] : 0…6; Protection area width (high light intensity) [m] : 3…18; Floating blanking : yes; Response time [ms] : 17; Applications : class C to EN 60654-1 weatherproof application; Ambient temperature [°C] : 0…55; Max. relative air humidity [%] : 95; ESPE type (IEC 61496-1) : 4; ISO 13849-1 : category 4, PL e; IEC 61508 : SIL 3; IEC 62061 : SIL cl 3; Mission time TM [h] : 175200; Safety-related reliability PFHD [1/h] : 1.9 E -08; Materials : housing: aluminium; front lens: PC; Length L [mm] : 1161; Items supplied : mounting bracket: 4 | slot nuts: 4 | screws
ConnectionConnector: 1 x M12
No. of inputs/outputsNumber of digital outputs: 2
Current consumption83 mA
Voltage supply24 V
Displaytransmitter: 3 x LED | transmitter: 7-segment LCD display | receiver: 3 x LED | receiver: 7-segment LCD display
Degree of protectionIP 65
Weight5605 g
Dimensions1161 x 35 x 45 mm

Downloads

PDF
IFM OY818S Datasheet PDF
Download