PI2203 - Ifm
Flush pressure sensor with display; Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Integrated watchdog : yes; Step response time analogue output [ms] : 45; Min. response time of switching output (dAP) [ms] : 3; Step response time analogue output [ms] : 7; Total number of outputs : 2; Output signal : switching signal; analogue signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Number of analogue outputs : 1; Analogue current output [mA] : 4...20, invertible; (scalable); Short-circuit protection : yes; Type of short-circuit protection : pulsed; Overload protection : yes; Measuring range : -1...25 bar: -14.4...362.7 psi: -0.1...2.5 MPa; Set point SP : -0.96...25 bar: -13.8...362.7 psi: -0.096...2.5 MPa; Reset point rP : -1...24.96 bar: -14.4...362.1 psi: -0.1...2.496 MPa; Analogue start point : -1...18.74 bar: -14.4...271.8 psi: -0.1...1.874 MPa; Analogue end point : 5.24...25 bar: 76.2...362.7 psi: 0.524...2.5 MPa; In steps of : 0.02 bar: 0.3 psi: 0.002 MPa; Factory setting : SP1 = 6.24 bar: rP1 = 5.74 bar | SP2 = 18.74 bar: rP2 = 18.24 bar | ASP = 0.00 bar: AEP = 25.00 bar; Switch point accuracy [% of the span] : < ± 0,2; (Turn down 1:1); Repeatability [% of the span] : < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1); Characteristics deviation [% of the span] : < ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1); Linearity deviation [% of the span] : < ± 0,15; (Turn down 1:1); Hysteresis deviation [% of the span] : < ± 0,15; (Turn down 1:1); Long-term stability [% of the span] : < ± 0,1; (Turn down 1:1; per year); Temperature coefficient zero point [% of the span / 10 K] : < ± 0,2; (0...200 °C); Temperature coefficient span [% of the span / 10 K] : < ± 0,15; (0...200 °C); Damping for the switching output dAP [s] : 0...30; Damping for the analogue output dAA [s] : 0.01...99.99; Communication interface : IO-Link; Transmission type : COM2 (38,4 kBaud); IO-Link revision : 1.0; SDCI standard : IO-Link Communication Specification, Version 1.0, January 2009, Ordner No: 10.002; Profiles : no profile; SIO mode : yes; Required master port type : A; Process data analogue : 1; Process data binary : 2; Min. process cycle time [ms] : 2.3; Supported DeviceIDs : Type of operation: DeviceID | Default: 102; Ambient temperature [°C] : -25...80; Note on ambient temperature : Medium temperature: ≤ 160 °C; Ambient temperature [°C] : -25...65; Note on ambient temperature : Medium temperature: ≤ 200 °C; Storage temperature [°C] : -25...100; Materials : stainless steel (1.4404 / 316L) stainless steel (1.4404 / 316L); stainless steel (1.4435 / 316L) stainless steel (1.4404 / 316L); PBT; PEI; PFA; Materials (wetted parts) : stainless steel (1.4435 / 316L) stainless steel (1.4404 / 316L); Min. pressure cycles : 10 million; Process connection : Clamp DN40 (1,5") DIN 32676 (ISO 2852); Surface characteristics Ra/Rz of the wetted parts : < 0.38 / -; Fill fluid for pressure transfer : NEOBEE (food grade, FDA compliant); Diaphragm diameter [mm] : 34; Display unit : bar; psi; MPa; % of the span; Connector: 1 x M12; Contacts: gold-plated