PI2817 - Ifm
Combined pressure sensor; Min. insulation resistance [MΩ] : 100;  (500 V DC); Protection class : III; Reverse polarity protection : yes; Integrated watchdog : yes; Step response time analogue output [ms] : 45; Min. response time of switching output (dAP) [ms] : 3; Step response time analogue output [ms] : 7; Total number of outputs : 2; Output signal : switching signal; analogue signal; IO-Link;  (configurable); Electrical design : PNP/NPN; Number of digital outputs : 2; Output function : normally open / normally closed;  (parameterisable); Number of analogue outputs : 1; Analogue current output [mA] : 4...20, invertible; (scalable); Short-circuit protection : yes; Type of short-circuit protection : pulsed; Overload protection : yes; Measuring range : -0.1...1.6 bar: -100...1600 mbar: -1.46...23.2 psi: -10...160 kPa; Set point SP : -96...1600 mbar: -1.4...23.2 psi: -9.6...160 kPa; Reset point rP : -100...1598 mbar: -1.44...23.16 psi: -10...159.8 kPa; Analogue start point : -100...1200 mbar: -1.46...17.42 psi: -10...120 kPa; Analogue end point : 300...1600 mbar: 4.34...23.2 psi: 30...160 kPa; In steps of : 2 mbar: 0.02 psi: 0.2 kPa; Factory setting : SP1 = 0.4 bar: rP1 = 0.368 bar | SP2 = 1.2 bar: rP2 = 1.168 bar | ASP = 0.0 bar: AEP = 1.6 bar; Switch point accuracy [% of the span] : < ± 0,2;  (Turn down 1:1); Repeatability [% of the span] : < ± 0,1;  (with temperature fluctuations < 10 K; Turn down 1:1); Characteristics deviation [% of the span] : < ± 0,2;  (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1); Linearity deviation [% of the span] : < ± 0,15;  (Turn down 1:1); Hysteresis deviation [% of the span] : < ± 0,15;  (Turn down 1:1); Long-term stability [% of the span] : < ± 0,1;  (Turn down 1:1; per year); Temperature coefficient zero point [% of the span / 10 K] : < ± 0,05;  (0...70 °C); Temperature coefficient span [% of the span / 10 K] : < ± 0,15;  (0...70 °C); Damping for the switching output dAP [s] : 0...30; Damping for the analogue output dAA [s] : 0.01...99.99; Communication interface : IO-Link; Transmission type : COM2 (38,4 kBaud); IO-Link revision : 1.0; Profiles : no profile; SIO mode : yes; Required master port type : A; Process data analogue : 1; Process data binary : 2; Min. process cycle time [ms] : 2.3; Supported DeviceIDs : Type of operation: DeviceID | Default: 727; Ambient temperature [°C] : -25...80; Storage temperature [°C] : -40...100; Materials : stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA; Materials (wetted parts) : ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE; Min. pressure cycles : 100 million; Process connection : threaded connection G 1 external thread sealing cone - Attention: The unit must only be installed in a process connection for G1 sealing cone.; The G1A sealing cone of the unit is only suited for adapters with metal end stop.; Display unit : mbar; kPa; psi; inH2O; mWS; % of the span