Skip to content
About Us
Select Brand
ABB
Schneider
Phoneix Contact
Siemens
Innomotics
Weidmuller
Gewiss
Fluke
SICK
Baumer
Dungs
Krom schroder
Festo
Norgren
Foxboro
Telemecanique
IFM
Pilz
Contact Us
About Us
Select Brand
ABB
Schneider
Phoneix Contact
Siemens
Innomotics
Weidmuller
Gewiss
Fluke
SICK
Baumer
Dungs
Krom schroder
Festo
Norgren
Foxboro
Telemecanique
IFM
Pilz
Contact Us
RFQ
Catalog
>
IFM
>
Process sensors
>
Flow sensors / flow meters
>
Ifm – SBU924
Ifm – SBU924
PROCESS SENSORS
⍾
Ifm – SBU924
Add to RFQ
Qty
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
>15
Flow transmitter with integrated backflow prevention; Operating voltage tolerance [%] : -15…10; Operating voltage [V] : 24 DC; (to SELV/PELV); Protection class : III; Reverse polarity protection : yes; Output signal : analogue signal; Analogue voltage output [V] : 0.5…10; Min. load resistance [Ω] : 10000; Short-circuit protection : yes; Overload protection : yes; Measuring range [l/min] : 2…50; Flow range [l/min] : 75; Repeatability [% of the final value] : 1; Measuring error [% of the final value] : ± 5; Response time [s] : < 0.01; Ambient temperature [°C] : 0…60; Storage temperature [°C] : -15…80; Materials : aluminium anodised; PA; Materials (wetted parts) : stainless steel (1.4401 / 316); brass; aluminium anodised; PU; O-ring: FKM; Process connection : G 1/2; Switching cycles mechanical : 10 million; Items supplied : sealing plugs
Connection
Connector: 1 x M12
No. of inputs/outputs
Number of digital outputs: 1
Current consumption
10 mA
Voltage supply
24 V
Display
switching status: 4 x LED, yellow
Degree of protection
IP 65; IP 67
Weight
742 g
Dimensions
u00d8 58 / L = 80.2 mm
Browse FLOW SENSORS / FLOW METERS catalog
Downloads
IFM SBU924 Datasheet PDF
Download
Related in
Flow sensors / flow meters
⍾ Page 11
« Prev page
Next page »
Product details
Add to RFQ
SI0555 - Ifm
Flow monitor; Response time [s] : 1...10; Operating voltage tolerance [%] : > -10; Operating voltage [V] : 48 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 10; Total number of outputs : 1; Output signal : switching signal; Electrical design : PNP; Number of digital outputs : 1; Output function : normally open / normally closed; (parameterisable); Max. voltage drop switching output DC [V] : 2.5; Permanent current rating of switching output DC [mA] : 250; Short-circuit protection : yes; Type of short-circuit protection : pulsed; Overload protection : yes; Probe length L [mm] : 45; Repeatability [cm/s] : 1...5; Note on repeatability : for water 5...100 cm/s; 25 °C | Factory setting; Temperature drift [cm/s x 1/K] : 0.1; (for water 5...100 cm/s; 10...70 °C); Temperature gradient [K/min] : 300; Switch point accuracy [cm/s] : ± 2...± 10; (for water 5...100 cm/s; 25 °C; Factory setting); Hysteresis [cm/s] : 2...5; (for water 5...100 cm/s; 25 °C; Factory setting); Adjustment of the switch point : pushbutton; Ambient temperature [°C] : -25...80; Storage temperature [°C] : -25...100; Thread designation : M18 x 1.5; Materials : stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PC; PBT-GF20; EPDM/X; Materials (wetted parts) : stainless steel (1.4404 / 316L); O-ring: FKM 80 Shore A; Process connection : M18 x 1,5 internal thread
Product details
Add to RFQ
SI0551 - Ifm
Flow monitor; Operating voltage [V] : 19...36 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 10; Total number of outputs : 1; Output signal : analogue signal; Number of analogue outputs : 1; Analogue current output [mA] : 4...20; Max. load [Ω] : 500; Overload protection : yes; Probe length L [mm] : 45; Flow range [cm/s] : 3...250; Greatest sensitivity [cm/s] : 3...100; Repeatability [cm/s] : 1...5; Note on repeatability : for water 5...100 cm/s; 25 °C | Factory setting; Temperature drift [cm/s x 1/K] : 0.1; (for water 5...100 cm/s; 10...70 °C); Response time [s] : 1...10; Ambient temperature [°C] : -25...80; Storage temperature [°C] : -25...100; Thread designation : M18 x 1.5; Materials : stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PC; PBT-GF20; EPDM/X; Materials (wetted parts) : stainless steel (1.4404 / 316L); O-ring: FKM 80 Shore A; Process connection : M18 x 1,5 internal thread
Product details
Add to RFQ
SF5702 - Ifm
Flow sensor for connection to an evaluation unit; Connection to control monitor : VS3000; Probe length L [mm] : 93; Setting range [cm/s] : 3...300; Greatest sensitivity [cm/s] : 3...60; Setting range [cm/s] : 200...3000; Greatest sensitivity [cm/s] : 200...800; Temperature gradient [K/min] : 300; Response time [s] : 1...10; Storage temperature [°C] : -25...80; Housing : for adapter; Thread designation : M18 x 1.5; Materials : titanium (3.7035); EPDM; ULTEM; Materials (wetted parts) : titanium (3.7035); O-ring: FKM 80 Shore A; Process connection : M18 x 1,5 internal thread
Product details
Add to RFQ
SI0521 - Ifm
Flow monitor; Operating voltage [V] : 24 DC; (18...32 DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 10; Total number of outputs : 2; Output signal : switching signal; Electrical design : PNP; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max. voltage drop switching output DC [V] : 2.5; Permanent current rating of switching output DC [mA] : 250; Short-circuit protection : yes; Type of short-circuit protection : pulsed; Overload protection : yes; Probe length L [mm] : 45; Setting range [cm/s] : 3...300; Greatest sensitivity [cm/s] : 3...100; Repeatability [% of Sr] : 1...5; Note on repeatability : for water 5...100 cm/s; 25 °C | Factory setting; Temperature drift [cm/s x 1/K] : 0.1; (for water 5...100 cm/s; 15...70 °C); Temperature gradient [K/min] : 300; Switch point accuracy [cm/s] : ± 10; (for water 5...100 cm/s; 25 °C; Factory setting); Hysteresis [cm/s] : 2...5; (for water 5...100 cm/s; 25 °C; Factory setting); Response time [s] : 1...10; Adjustment of the switch point : pushbutton; Ambient temperature [°C] : -25...80; Storage temperature [°C] : -25...100; Thread designation : M18 x 1.5; Materials : stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PC; PBT-GF20; EPDM/X; Materials (wetted parts) : stainless steel (1.4404 / 316L); O-ring: FKM 80 Shore A; Process connection : M18 x 1,5 internal thread
Product details
Add to RFQ
SF5700 - Ifm
Flow sensor for connection to an evaluation unit; Connection to control monitor : VS3000; Probe length L [mm] : 45; Setting range [cm/s] : 3...300; Greatest sensitivity [cm/s] : 3...60; Setting range [cm/s] : 200...3000; Greatest sensitivity [cm/s] : 200...800; Temperature gradient [K/min] : 300; Response time [s] : 1...10; Storage temperature [°C] : -25...80; Housing : for adapter; Thread designation : M18 x 1.5; Materials : stainless steel (1.4404 / 316L); EPDM; Materials (wetted parts) : titanium (3.7035); O-ring: FKM 80 Shore A; Process connection : M18 x 1,5 internal thread
Product details
Add to RFQ
SI0550 - Ifm
Flow monitor; Response time [s] : < 1; Operating voltage [V] : 19...36 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 10; Total number of outputs : 1; Output signal : switching signal; Electrical design : PNP; Number of digital outputs : 1; Output function : normally open / normally closed; (parameterisable); Max. voltage drop switching output DC [V] : 2.5; Permanent current rating of switching output DC [mA] : 250; Short-circuit protection : yes; Type of short-circuit protection : pulsed; Overload protection : yes; Probe length L [mm] : 45; Repeatability [cm/s] : 1...5; Temperature drift [cm/s x 1/K] : 0.1; Switch point accuracy [cm/s] : ± 2...± 10; Hysteresis [cm/s] : 2...5; Adjustment of the switch point : pushbutton; Ambient temperature [°C] : -25...80; Storage temperature [°C] : -25...100; Thread designation : M18 x 1.5; Materials : stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PC; PBT-GF20; EPDM/X; Materials (wetted parts) : stainless steel (1.4404 / 316L); O-ring: FKM 80 Shore A; Process connection : M18 x 1,5 internal thread
Product details
Add to RFQ
SF5704 - Ifm
Flow sensor for connection to an evaluation unit; Connection to control monitor : VS3000; Probe length L [mm] : 243; Setting range [cm/s] : 3...300; Greatest sensitivity [cm/s] : 3...60; Setting range [cm/s] : 200...3000; Greatest sensitivity [cm/s] : 200...800; Temperature gradient [K/min] : 300; Response time [s] : 1...10; Storage temperature [°C] : -25...80; Housing : for adapter; Thread designation : M18 x 1.5; Materials : titanium (3.7035); EPDM; ULTEM; Materials (wetted parts) : titanium (3.7035); O-ring: FKM 80 Shore A; Process connection : M18 x 1,5 internal thread
Product details
Add to RFQ
SI0556 - Ifm
Flow monitor; Response time [s] : 1...10; Operating voltage [V] : 19...36 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 10; Total number of outputs : 2; Output signal : switching signal; Electrical design : PNP; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max. voltage drop switching output DC [V] : 2.5; Permanent current rating of switching output DC [mA] : 250; Short-circuit protection : yes; Type of short-circuit protection : pulsed; Overload protection : yes; Probe length L [mm] : 45; Repeatability [cm/s] : 1...5; Note on repeatability : for water 5...100 cm/s; 25 °C | Factory setting; Temperature drift [cm/s x 1/K] : 0.1; (for water 5...100 cm/s; 10...70 °C); Temperature gradient [K/min] : 300; Switch point accuracy [cm/s] : ± 2...± 10; (for water 5...100 cm/s; 25 °C; Factory setting); Hysteresis [cm/s] : 2...5; (for water 5...100 cm/s; 25 °C; Factory setting); Adjustment of the switch point : pushbutton; Ambient temperature [°C] : -25...80; Storage temperature [°C] : -25...100; Thread designation : M18 x 1.5; Materials : stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PC; PBT-GF20; EPDM/X; Materials (wetted parts) : stainless steel (1.4404 / 316L); O-ring: FKM 80 Shore A; Process connection : M18 x 1,5 internal thread
Product details
Add to RFQ
SF6200 - Ifm
Flow sensor for connection to an evaluation unit; Response time [s] : 1...10; Connection to control monitor : VS3000; Probe length L [mm] : 15...156; Temperature gradient [K/min] : 30; Materials : stainless steel (1.4404 / 316L) several parts, welded; Materials (wetted parts) : stainless steel (1.4404 / 316L) several parts, welded; Process connection : Ø 10 mm; Accessories (optional) : Clamp adapter: R 1/2, E40160 | Clamp adapter: 1/2" NPT, E40174
Product details
Add to RFQ
SF5703 - Ifm
Flow sensor for connection to an evaluation unit; Connection to control monitor : VS3000; Probe length L [mm] : 143; Setting range [cm/s] : 3...300; Greatest sensitivity [cm/s] : 3...60; Setting range [cm/s] : 200...3000; Greatest sensitivity [cm/s] : 200...800; Temperature gradient [K/min] : 300; Response time [s] : 1...10; Storage temperature [°C] : -25...80; Housing : for adapter; Thread designation : M18 x 1.5; Materials : titanium (3.7035); EPDM; ULTEM; Materials (wetted parts) : titanium (3.7035); O-ring: FKM 80 Shore A; Process connection : M18 x 1,5 internal thread
Product details
Add to RFQ
SF5701 - Ifm
Flow sensor for connection to an evaluation unit; Connection to control monitor : VS3000; Probe length L [mm] : 63; Setting range [cm/s] : 3...300; Greatest sensitivity [cm/s] : 3...60; Setting range [cm/s] : 200...3000; Greatest sensitivity [cm/s] : 200...800; Temperature gradient [K/min] : 300; Response time [s] : 1...10; Storage temperature [°C] : -25...80; Housing : for adapter; Thread designation : M18 x 1.5; Materials : titanium (3.7035); EPDM; ULTEM; Materials (wetted parts) : titanium (3.7035); O-ring: FKM 80 Shore A; Process connection : M18 x 1,5 internal thread
Product details
Add to RFQ
SF320A - Ifm
Flow sensor for connection to an evaluation unit; Response time [s] : 1...10; Connection to control monitor : VS2000 Exi (PTB 01 ATEX 2075); Probe length L [mm] : 12; Temperature gradient [K/min] : 15; Ambient temperature [°C] : -20...70; Max. internal capacitance [nF] : 0.4; Max. internal inductance [µH] : 2; Temperature class : T4; Housing : threaded type; Materials : stainless steel (1.4404 / 316L); Materials (wetted parts) : stainless steel (1.4404 / 316L); Process connection : G 1/2 external thread; Installation length EL [mm] : 45