Ifm – SD9000

PROCESS SENSORS Ifm – SD9000
Qty
Compressed air meter; Operating voltage [V] : 18…30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 1; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; IO-Link; (configurable); Electrical design : PNP; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max. voltage drop switching output DC [V] : 2; Permanent current rating of switching output DC [mA] : 250; (per output); Number of analogue outputs : 1; Analogue current output [mA] : 4…20; (scalable); Max. load [Ω] : 500; Pulse output : consumed quantity meter; Short-circuit protection : yes; Type of short-circuit protection : pulsed; Overload protection : yes; Measuring range : 20…6835 l/min: 0.3…95.3 m/s: 1.5…410 m³/h; Display range : 0…8200 l/min: 0…114.4 m/s: 0…492 m³/h; Set point SP : 55…6835 l/min: 0.8…95.3 m/s: 3.5…410 m³/h; Reset point rP : 20…6800 l/min: 0.3…94.8 m/s: 1.5…408 m³/h; Analogue start point ASP : 0…5125 l/min: 0…71.5 m/s: 0…307.5 m³/h; Analogue end point AEP : 1710…6835 l/min: 23.8…95.3 m/s: 102.5…410 m³/h; In steps of : 5 l/min: 0.1 m/s: 0.5 m³/h; Pulse value : 0.005…4 000 000 m³; In steps of : 0.001 m³; Pulse length [s] : 0,018…2; Accuracy [K] : ± 2; (medium flow in the limit area of the flow measurement range); Response time [s] : 0.1; (dAP = 0); Damping for the switching output dAP in steps [s] : 0 – 0,2 – 0,4 – 0,6 – 0,8 – 1; Parameter setting options : Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser; Communication interface : IO-Link; Transmission type : COM2 (38,4 kBaud); IO-Link revision : 1.1; SDCI standard : IEC 61131-9 CDV; Profiles : no profile; SIO mode : yes; Required master port type : A; Process data analogue : 3; Process data binary : 2; Min. process cycle time [ms] : 4.1; Supported DeviceIDs : Type of operation: DeviceID | Default: 269; Ambient temperature [°C] : 0…60; Storage temperature [°C] : -20…85; Max. relative air humidity [%] : 90; Materials : PBT-GF20; NBR; PC; stainless steel (1.4301 / 304); PTFE; brass coated; aluminium powder-coated; Materials (wetted parts) : stainless steel (1.4301 / 304); FKM; ceramics glass passivated; PEEK GF30; polyester; aluminium; Process connection : threaded connection R 1 1/2 DN40
Connection Connector: 1 x M12
No. of inputs/outputs Number of digital outputs: 2; Number of analogue outputs: 1
Current consumption < 110 mA
Voltage supply 24 V
Display Display unit: 5 x LED, green (Nl/min, Nmu00b3/h, Nm/s, Nmu00b3, u00b0C) | function display: 1 x LED, green | switching status: 2 x LED, yellow | measured values: alphanumeric display, 4-digit | programming: alphanumeric display, 4-digit
Degree of protection IP 65
Weight 4004 g
Dimensions u00d8 58 / L = 80.2 mm

Downloads

PDF
IFM SD9000 Datasheet PDF
Download