Ifm – SM6000

Qty
Magnetic-inductive flow meter; Operating voltage [V] : 18…30 DC; (according to EN 50178 SELV/PELV); Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max. voltage drop switching output DC [V] : 2; Permanent current rating of switching output DC [mA] : 200; Number of analogue outputs : 1; Analogue current output [mA] : 4…20; (scalable); Max. load [Ω] : 500; Analogue voltage output [V] : 0…10; (scalable); Min. load resistance [Ω] : 2000; Pulse output : flow rate meter; Short-circuit protection : yes; Type of short-circuit protection : pulsed; Overload protection : yes; Measuring range : 0.1…25 l/min: 0.005…1.5 m³/h; Display range : -30…30 l/min: -1.8…1.8 m³/h; Resolution : 0.02 l/min: 0.002 m³/h; Set point SP : 0.25…25 l/min: 0.015…1.5 m³/h; Reset point rP : 0.1…24.9 l/min: 0.005…1.495 m³/h; Analogue start point ASP : 0…20 l/min: 0…1.2 m³/h; Analogue end point AEP : 5…25 l/min: 0.3…1.5 m³/h; In steps of : 0.02 l/min: 0.002 m³/h; Pulse value : 0.00001…30 000 m³; Pulse length [s] : 0,01…2; Dynamic response T05 / T09 [s] : T09 = 20 (Q > 1 l/min); Response time [s] : 0.15; (dAP = 0, T19); Delay time programmable dS, dr [s] : 0…50; Damping for the switching output dAP [s] : 0…5; Parameter setting options : Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit; Communication interface : IO-Link; Transmission type : COM2 (38,4 kBaud); IO-Link revision : 1.1; SDCI standard : IEC 61131-9; Profiles : Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis; SIO mode : yes; Required master port type : A; Process data analogue : 3; Process data binary : 2; Min. process cycle time [ms] : 5; Supported DeviceIDs : Type of operation: DeviceID | Default: 569; Ambient temperature [°C] : -10…60; Storage temperature [°C] : -25…80; Materials : stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE; Materials (wetted parts) : stainless steel (1.4404 / 316L); PEEK; FKM; Process connection : threaded connection G 1/2 DN15 flat seal

Downloads

PDF
IFM SM6000 Datasheet PDF
Download