Ifm – SM8601

IO-LINK PROCESS SENSORS Ifm – SM8601
Qty
Operating voltage [V] : 18…30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max. voltage drop switching output DC [V] : 2; Permanent current rating of switching output DC [mA] : 200; Number of analogue outputs : 1; Analogue current output [mA] : 4…20; (scalable); Max. load [Ω] : 500; Analogue voltage output [V] : 0…10; (scalable); Min. load resistance [Ω] : 2000; Pulse output : flow rate meter; Short-circuit protection : yes; Type of short-circuit protection : pulsed; Overload protection : yes; Measuring range : 6…1584 gph: 0.1…26.4 gpm; Display range : -1902…1902 gph: -31.7…31.7 gpm; Resolution : 2 gph: 0.05 gpm; Set point SP : 14…1586 gph: 0.25…26.4 gpm; Reset point rP : 6…1578 gph: 0.1…26.25 gpm; Analogue start point ASP : 0…1272 gph: 0…21.2 gpm; Analogue end point AEP : 312…1586 gph: 5.2…26.4 gpm; In steps of : 2 gph: 0.05 gpm; Pulse value : 0.01…100 000 000 gal; Pulse length [s] : 0,0025…2; Dynamic response T05 / T09 [s] : T09 = 20 (Q > 0,26 gpm); Response time [s] : 0.15; (dAP = 0, T19); Delay time programmable dS, dr [s] : 0…50; Damping for the switching output dAP [s] : 0…5; Parameter setting options : Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit; Communication interface : IO-Link; Transmission type : COM2 (38,4 kBaud); IO-Link revision : 1.1; SDCI standard : IEC 61131-9; Profiles : Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis; SIO mode : yes; Required master port type : A; Process data analogue : 3; Process data binary : 2; Min. process cycle time [ms] : 5; Supported DeviceIDs : Type of operation: DeviceID | Default: 576; Ambient temperature [°F] : 14…140; Storage temperature [°F] : -13…176; Materials : stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE; Materials (wetted parts) : stainless steel (1.4404 / 316L); PEEK; FKM; Process connection : threaded connection 1″ NPT DN25
ConnectionConnector: 1 x M12; Contacts: gold-plated
No. of inputs/outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Current consumption95; (24 V) mA
Voltage supply24 V
DisplayDisplay unit: 6 x LED, green (gpm, gph, gal, u00b0F, 10u00b3, 1000 x 10u00b3) | switching status: 2 x LED, yellow | measured values: alphanumeric display, 4-digit | programming: alphanumeric display, 4-digit
Degree of protectionIP 67
Weight698.5 g
Dimensionsu00d8 23 / L = 142 mm