SM6601 - Ifm
Magnetic-inductive flow meter; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max. voltage drop switching output DC [V] : 2; Permanent current rating of switching output DC [mA] : 200; Number of analogue outputs : 1; Analogue current output [mA] : 4...20; (scalable); Max. load [Ω] : 500; Analogue voltage output [V] : 0...10; (scalable); Min. load resistance [Ω] : 2000; Pulse output : flow rate meter; Short-circuit protection : yes; Type of short-circuit protection : pulsed; Overload protection : yes; Measuring range : 1.5...396 gph: 0.03...6.6 gpm; Display range : -475.5...475.5 gph: -7.925...7.925 gpm; Resolution : 0.5 gph: 0.01 gpm; Set point SP : 3.5...396.5 gph: 0.06...6.6 gpm; Reset point rP : 1.5...394 gph: 0.03...6.57 gpm; Analogue start point ASP : 0...318 gph: 0...5.3 gpm; Analogue end point AEP : 78...396 gph: 1.3...6.6 gpm; In steps of : 0.5 gph: 0.01 gpm; Pulse value : 0.01...30 000 000 gal; Pulse length [s] : 0,01...2; Dynamic response T05 / T09 [s] : T09 = 20 (Q > 0,26 gpm); Response time [s] : 0.15; (dAP = 0, T19); Delay time programmable dS, dr [s] : 0...50; Damping for the switching output dAP [s] : 0...5; Parameter setting options : Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit; Communication interface : IO-Link; Transmission type : COM2 (38,4 kBaud); IO-Link revision : 1.1; SDCI standard : IEC 61131-9; Profiles : Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis; SIO mode : yes; Required master port type : A; Process data analogue : 3; Process data binary : 2; Min. process cycle time [ms] : 5; Supported DeviceIDs : Type of operation: DeviceID | Default: 570; Ambient temperature [°F] : 14...140; Storage temperature [°F] : -13...176; Materials : stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE; Materials (wetted parts) : stainless steel (1.4404 / 316L); PEEK; FKM; Process connection : threaded connection 1/2" NPT DN15