Catalog>SICK>Encoders>Measuring wheel encoders>DUV60>Sick – DUV60E-Z4KZWAZAS04

Sick – DUV60E-Z4KZWAZAS04

MEASURING WHEEL ENCODERS Sick – DUV60E-Z4KZWAZAS04
Qty
Features: Special device: ✔; Specialty: MS 6-pin connector at the end of a 500 mm cable, DIP switches pre-set to HTL output; Standard reference device: DUV60E-D4KKWADA, 1090501; Performance: Linear resolution: 0.125 mm/pulse to 304.8 mm/pulse (type-dependent); Pulses per revolution: 1 … 1500 1); Measuring step: 90° electric/pulses per revolution; Measuring increment (resolution in mm/pulse): / pulses per revolution; Measuring step deviation: ± 18°, / pulses per revolution; Error limits: Measuring step deviation x 3; Duty cycle: 0.5 ± 5 %; Initialization time: < 5 ms 2); Interfaces: Communication interface: Incremental; Communication Interface detail: HTL; Parameterising data: DIP switch, selectable output; Electrical data: Operating power consumption (no load): 120 mA; Connection type: Cable, 8-wire, universal, 500 mm 1); Pulses per revolution: ✔; Output voltage: ✔; Direction of rotation: ✔; Power consumption max. without load: ≤ 1.25 W; Supply voltage: 4.75 V … 30 V; Load current max.: ≤ 30 mA, per channel; Maximum output frequency: 60 kHz; Reference signal, number: 1; Reference signal, position: 180°, electric, gated with A; Reverse polarity protection: ✔; Short-circuit protection of the outputs: ✔; MTTFd: mean time to dangerous failure: 275 years (EN ISO 13849-1) 2); Mechanical data: Spring arm design: Without mount; Mass: 0.9 kg 1); Shaft: Stainless steel; Flange: Aluminum; Housing: Aluminum; Cable: PVC; Spring element: Spring steel; Measuring wheel, spring arm: Aluminum; Start up torque: 0.5 Ncm; Operating torque: 0.4 Ncm; Operating speed: 1,500 min⁻¹; Bearing lifetime: 3.6 x 109 revolutions; Maximum travel/deflection of spring arm: 40 mm 2); Recommended pretension: 20 mm 2); Max. permissible working area for the spring (continuous operation): ± 10 mm; Ambient data: EMC: According to EN 61000-6-2 and EN 61000-6-3; Permissible relative humidity: 90 % (condensation of the optical scanning not permitted); Operating temperature range: –30 °C … +70 °C; Storage temperature range: –40 °C … +75 °C; Classifications: ECl@ss 5.0: 27270501; ECl@ss 5.1.4: 27270501; ECl@ss 6.0: 27270590; ECl@ss 6.2: 27270590; ECl@ss 7.0: 27270501; ECl@ss 8.0: 27270501; ECl@ss 8.1: 27270501; ECl@ss 9.0: 27270501; ECl@ss 10.0: 27270790; ECl@ss 11.0: 27270707; ETIM 5.0: EC001486; ETIM 6.0: EC001486; ETIM 7.0: EC001486; UNSPSC 16.0901: 41112113

Downloads

PDF
SICK DUV60E-Z4KZWAZAS04 Datasheet PDF (en)
Download
PDF
SICK DUV60E-Z4KZWAZAS04 Datasheet PDF (de)
Download
PDF
SICK DUV60E-Z4KZWAZAS04 Datasheet PDF (ru)
Download
PDF
SICK DUV60E-Z4KZWAZAS04 Datasheet PDF (pl)
Download

Related in DUV60 ⍾ Page 1