M20E-091A3A222 - Sick
Safety-related parameters: Type: Type 2 (IEC 61496-1); Safety integrity level: SIL1 (IEC 61508)SILCL1 (EN 62061); Category: Category 2 (EN ISO 13849); Test rate (internal test): 13 /s (EN ISO 13849) 1); Maximum demand rate: ≤ 8 min⁻¹ (EN ISO 13849) 2); Performance level: PL c (EN ISO 13849); PFHD (mean probability of a dangerous failure per hour): 6.6 x 10-9 (EN ISO 13849); TM (mission time): 20 years (EN ISO 13849); Safe state in the event of a fault: At least one OSSD is in the OFF state.; Functions: Beam coding: ✔; Interfaces: System connectionMale connector M12, 8-pinConductor cross-section0.25 mm²: System connection; Configuration methodHard wired: Configuration method; Display elements: LEDs7-segment display; Fieldbus, industrial networkIntegration via Flexi Soft safety controllerCANopen DeviceNet™ EtherCAT® EtherNet/IP™Modbus TCPPROFIBUS DPPROFINET: Fieldbus, industrial network; Electrical data: Protection class: III (IEC 61140); Supply voltage VS: 24 V DC (19.2 V DC ... 28.8 V DC) 1); Output signal switching devices (OSSDs): 2 PNP semiconductors, short-circuit protected, cross-circuit monitored; Mechanical data: Dimensions: See dimensional drawing; Housing cross-section: 48 mm x 40 mm; Ambient data: Enclosure rating: IP65 (EN 60529); Air humidity: 15 % ... 95 %, Non-condensing; Vibration resistance: 5 g, 10 Hz ... 55 Hz (IEC 60068-2-6); Shock resistance: 10 g, 16 ms (IEC 60068-2-29); Classifications: ECl@ss 5.0: 27272703; ECl@ss 5.1.4: 27272703; ECl@ss 6.0: 27272703; ECl@ss 6.2: 27272703; ECl@ss 7.0: 27272703; ECl@ss 8.0: 27272703; ECl@ss 8.1: 27272703; ECl@ss 9.0: 27272703; ECl@ss 10.0: 27272703; ECl@ss 11.0: 27272703; ETIM 5.0: EC001832; ETIM 6.0: EC001832; ETIM 7.0: EC001832; UNSPSC 16.0901: 46171620