Siemens – 7MF4033-1FA10-1AB7-Z A01
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning 1.6 to 160 bar g (23.2 to 2320 psi g), Overload limit 250 bar, Diaphragm stainless steel, measuring cell stainless steel Female thread 1/2-14 NPT Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable gland M20 x 1.5 Housing cover with window (digital indicator visible, customized adjustment supplement Y21 required) With steel mounting bracket Rating plate inscriptions in Englisch, pressure units in H2O resp. psi Test certificate according to standard IEC 60770-2 Inspection certificate EN 10204-3.1: certificate pressurised parts Factory certificate to DIN 50 049-2.2 / EN 10 204-2.2 Range (linear characteristic) specify in plain text:, Y01:… to …mBar,kpa,mpa,… Stainless steel tag plate (measuring point description) Max.16 character, specify in plain text: Adjustment digital indicator specify plain text Y21: mBar, bar, kpa, mpa,…