[siemens_summary]
[catalog_children]
[catalog_search_products]
3UG Monitoring Relays

3UG Monitoring Relays

Items 25 - 36 of 107 from Siemens ⍾ Last modified Sep 7, 2025

3UG Monitoring Relays ⍾ Page 3

Product detailsAdd to RFQ
3UG4832-1AA40 - Siemens
Digital monitoring relay Voltage monitoring, 22.5 mm for IO-Link 10...600 V AC/DC Overvoltage and undervoltage Hysteresis 0.1 to 300 V ON-delay time Tripping delay time 1 change-over contact, screw terminal
Product detailsAdd to RFQ
3UG4825-1CA40 - Siemens
Digital monitoring relay for residual current monitoring with residual-current transformer 3UL23 for IO-Link Setting range 0.03 A to 40 A separate for warning threshold and switch-off value ON delay and tripping delay 0 to 999.9 s Shutdown hysteresis up to 50% Warning hysteresis 5% fixed Width 22.5mm, 2 change-over contacts with or without fault buffer screw terminal
Product detailsAdd to RFQ
3UG4851-2AA40 - Siemens
DIGITAL MONITORING RELAY SPEED MONITORING, FOR IO-LINK FROM 0.1 TO 2200 RPM OVERSHOOT AND UNDERSHOOT ON DELAY TIME TRIPPING DELAY TIME HYSTERESIS 0.1 TO 99 RPM 1 CHANGE-OVER CONTACT, SPRING-LOADED TERMINAL
Product detailsAdd to RFQ
3UG4651-1AW30 - Siemens
Digital monitoring relay Speed monitoring from 0.1 to 2200 rpm Overshoot and undershoot 24 to 240 V AC/DC 50 to 60 Hz DC and AC ON delay 1 to 900 s Tripping delay 0.1 to 99.9 s Hysteresis 0.1 to 99 rpm 1 change-over contact with or without fault buffer screw terminal Successor product for 3UG3051
Product detailsAdd to RFQ
3UG4822-2AA40 - Siemens
Digital monitoring relay Current monitoring, 22.5 mm for IO-Link 0.05...10.0 A AC/DC Overcurrent and undercurrent Transformer scaling factor Hysteresis 0.01 to 5.0 A ON-delay time Tripping delay time 1 change-over contact, spring-type connection system
Product detailsAdd to RFQ
3UG4822-1AA40 - Siemens
Digital monitoring relay Current monitoring, 22.5 mm for IO-Link 0.05...10.0 A AC/DC Overcurrent and undercurrent Transformer scaling factor Hysteresis 0.01 to 5.0 A ON-delay time Tripping delay time 1 change-over contact, screw terminal
Product detailsAdd to RFQ
3UG4816-2AA40 - Siemens
Digital monitoring relay for 3-phase voltage with N-conductor for IO-Link 50...60 Hz AC 3 x 160 to 690 V Phase sequence, Phase failure Phase asymmetry Undervoltage and overvoltage Hysteresis 1-20 V Line stabilization delay Tripping delay time 1 change-over contact, spring-type connection system
Product detailsAdd to RFQ
3UG4816-1AA40 - Siemens
Digital monitoring relay for 3-phase voltage with N-conductor for IO-Link 50...60 Hz AC 3 x 160 to 690 V Phase sequence, Phase failure Phase asymmetry Undervoltage and overvoltage Hysteresis 1-20 V Line stabilization delay Tripping delay time 1 change-over contact, screw terminal
Product detailsAdd to RFQ
3UG4651-2AA30 - Siemens
Digital monitoring relay Speed monitoring from 0.1 to 2200 rpm 0vershoot and undershoot Supply voltage: 24 V AC/DC 50 to 60 Hz DC and AC without galvanic isolation to measuring circuit ON delay 1 to 900 s Tripping delay 0.1 to 99.9 s Hysteresis 0.1 to 99 rpm 1 change-over contact with or without fault buffer spring-type connection system
Product detailsAdd to RFQ
3UG4815-2AA40 - Siemens
DIGITAL MONITORING RELAY FOR 3-PHASE MAINS VOLTAGE FOR IO-LINK AC 50 TO 60 HZ 3X 160 TO 690V LINE PHASE SEQUENCE, PHASE FAILURE, PHASE ASYMMETRY UNDER- AND OVERVOLTAGE HYSTERESIS 1-20V NETWORK STABILITY TIME TRIGGER DELAY TIME 1 CHANGEOVER, SPRING BALANCER TECHNOLOGY
Product detailsAdd to RFQ
3UG4651-2AW30 - Siemens
Digital monitoring relay Speed monitoring from 0.1 to 2200 rpm Overshoot and undershoot 24 to 240 V AC/DC 50 to 60 Hz DC and AC ON delay 1 to 900 s Tripping delay 0.1 to 99.9 s Hysteresis 0.1 to 99 rpm 1 change-over contact with or without fault buffer spring-type connection system
Product detailsAdd to RFQ
3UG4631-2AA30 - Siemens
Digital monitoring relay Voltage monitoring, 22.5 mm from 0.1-60 V AC/DC 0vershoot and undershoot Supply voltage: 24 V AC/DC 50 to 60 Hz DC and AC without galvanic isolation to measuring circuit Noise pulses delay 0.1 to 20 s Hysteresis 0.1 to 30 V 1 change-over contact with or without fault buffer spring-type connection system